CoChat

Distal Radius in Adolescent Girls with Anorexia Nervosa: Trabecular Structure Analysis with High-Resolution Flat-Panel Volume CT

Open access
Bredella, Miriam A., Misra, Madhusmita, Miller, Karen K., Madisch, Ijad, Sarwar, Ammar, Cheung, Arnold, Klibanski, Anne, Gupta, Rajiv · 2008 · Radiology
Cited by 96

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To examine trabecular microarchitecture with high-resolution flat-panel volume computed tomography (CT) and bone mineral density (BMD) with dual-energy x-ray absorptiometry (DXA) in adolescent girls with anorexia nervosa (AN) and to compare these results with those in normal-weight control subjects. MATERIALS AND METHODS: The study was approved by the institutional review board and complied with HIPAA guidelines. Informed consent was obtained. Twenty adolescent girls, 10 with mild AN (mean age, 15.9 years; range, 13-18 years) and 10 age- and sex-matched normal-weight control subjects (mean age, 15.9 years; range, 12-18 years) underwent flat-panel volume CT of distal radius to determine apparent trabecular bone volume fraction (BV/TV), apparent trabecular number (TbN), apparent trabecular thickness (TbTh), and apparent trabecular separation (TbSp). All subjects underwent DXA of spine, hip, and whole body to determine BMD and body composition. The means and standard deviations (SDs) of structure parameters were calculated for AN and control groups. Groups were compared (Student t test). Linear regression analysis was performed. RESULTS: AN subjects compared with control subjects, respectively, showed significantly lower mean values for BV/TV (0.37% +/- 0.05 [SD] vs 0.46% +/- 0.03, P = .0002) and TbTh (0.31 mm +/- 0.03 vs 0.39 mm +/- 0.03, P < .0001) and higher mean values for TbSp (0.54 mm +/- 0.13 vs 0.44 mm +/- 0.04, P = .02). TbN was lower in AN subjects than in control subjects, but the difference was not significant (1.17 mm(-3) +/- 0.15 vs 1.22 mm(-3) +/- 0.07, P = .43). There was no significant difference in BMD between AN and control subjects. BMD parameters showed positive correlation with BV/TV and TbTh in the control group (r = 0.55-0.84, P = .05-.01) but not in AN patients. CONCLUSION: Flat-panel volume CT is effective in evaluation of trabecular structure in adolescent girls with AN and demonstrates that bone structure is abnormal in these patients compared with that in normal-weight control subjects despite normal BMD. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/249/3/938/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2492080173

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 96

Metadata

Authors
Bredella, M. A., Misra, M., Miller, K. K., Madisch, I., Sarwar, A., Cheung, A., Klibanski, A., & Gupta, R.
Venue
Radiology
Published
2008-12
Volume
249
Issue
3
Pages
938-946
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2146900705
Cited by
96
References
1
FWCI
6.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distal Radius in Adolescent Girls with Anorexia Nervosa: Trabecular Structure Analysis with High-Resolution Flat-Panel Volume CT. https://app.cochat.ai/papers/10.1148/radiol.2492080173
The paper
Bredella, M. A., Misra, M., Miller, K. K., Madisch, I., Sarwar, A., Cheung, A., Klibanski, A., & Gupta, R. (2008). Distal Radius in Adolescent Girls with Anorexia Nervosa: Trabecular Structure Analysis with High-Resolution Flat-Panel Volume CT. Radiology. https://doi.org/10.1148/radiol.2492080173

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.