The DOI matches its Crossref record.
Breast Imaging Reporting and Data System Lexicon for US: Interobserver Agreement for Assessment of Breast Masses
Abstract
PURPOSE: To retrospectively evaluate the interobserver agreement of radiologists who used the Breast Imaging Reporting and Data System (BI-RADS) lexicon to characterize and categorize ultrasonographic (US) features of breast masses. MATERIALS AND METHODS: No institutional review board approval or patient consent was required. Five breast radiologists retrospectively independently evaluated 267 breast masses (113 benign and 154 malignant masses in 267 patients) by using the BI-RADS US lexicon. Reviewers were blinded to mammographic images, medical history, and pathologic findings. Interobserver agreement was assessed with the Aickin revised kappa statistic. RESULTS: Interobserver agreement varied from fair for evaluation of mass margins (kappa = 0.36) to moderate for evaluation of lesion boundary (kappa = 0.48), echo pattern (kappa = 0.58), and posterior acoustic features (kappa = 0.47) to substantial for evaluation of mass orientation (kappa = 0.70) and shape (kappa = 0.64). For small (< or =0.7 cm; n = 49) or malignant (n = 154) masses, low concordance was noted for margin descriptors (kappa = 0.30 and 0.28, respectively) and BI-RADS category (kappa = 0.21 and 0.26, respectively). Overall, only fair agreement was obtained for BI-RADS category (kappa = 0.30). Agreement for subdivisions 4a, 4b, and 4c of BI-RADS category 4 was fair (kappa = 0.33), fair (kappa = 0.32), and poor (kappa = 0.17), respectively. CONCLUSION: Reproducibility of US BI-RADS terminology is good except for margin evaluation. A trend toward lower concordance was noted for the evaluation of small masses and malignant lesions. Classification into subdivisions 4a, 4b, and 4c was poorly reproducible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kwak, J. Y., Han, K. H., Yoon, J. H., Moon, H. J., Son, E. J., Park, S. H., Jung, H. K., Choi, J. S., Kim, B. M., & Kim, E.-K. (2011) · Radiology · doi:10.1148/radiol.11110206 · Cited by 1,101
Rosenkrantz, A. B., Ginocchio, L. A., Cornfeld, D., Froemming, A. T., Gupta, R. T., Turkbey, B., Westphalen, A. C., Babb, J. S., & Margolis, D. J. (2016) · Radiology · doi:10.1148/radiol.2016152542 · Cited by 501
Shear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406
Breast Ultrasonography: State of the Art
Hooley, R. J., Scoutt, L. M., & Philpotts, L. E. (2013) · Radiology · doi:10.1148/radiol.13121606 · Cited by 324
Qian, X., Pei, J., Zheng, H., Xie, X., Yan, L., Zhang, H., Han, C., Gao, X., Zhang, H., Zheng, W., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00711-2 · Cited by 253
Metadata
- Authors
- Abdullah, N., Mesurolle, B., El-Khoury, M., & Kao, E.
- Venue
- Radiology
- Published
- 2009-09
- Volume
- 252
- Issue
- 3
- Pages
- 665-672
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2168191810
- Cited by
- 205
- References
- 0
- FWCI
- 8.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breast Imaging Reporting and Data System Lexicon for US: Interobserver Agreement for Assessment of Breast Masses. https://app.cochat.ai/papers/10.1148/radiol.2523080670
- The paper
- Abdullah, N., Mesurolle, B., El-Khoury, M., & Kao, E. (2009). Breast Imaging Reporting and Data System Lexicon for US: Interobserver Agreement for Assessment of Breast Masses. Radiology. https://doi.org/10.1148/radiol.2523080670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.