CoChat

When Radiologists Perform Best: The Learning Curve in Screening Mammogram Interpretation

Open access
Miglioretti, Diana L., Gard, Charlotte C., Carney, Patricia A., Onega, Tracy L., Buist, Diana S. M., Sickles, Edward A., Kerlikowske, Karla, Rosenberg, Robert D., Yankaskas, Bonnie C., Geller, Berta M., Elmore, Joann G. · 2009 · Radiology
Cited by 137

The DOI matches its Crossref record.

Abstract

PURPOSE: To examine changes in screening mammogram interpretation as radiologists with and radiologists without fellowship training in breast imaging gain clinical experience. MATERIALS AND METHODS: In an institutional review board-approved HIPAA-compliant study, the performance of 231 radiologists who interpreted screen-film screening mammograms from 1996 to 2005 at 280 facilities that contribute data to the Breast Cancer Surveillance Consortium was examined. Radiologists' demographic data and clinical experience levels were collected by means of a mailed survey. Mammograms were grouped on the basis of how many years the interpreting radiologist had been practicing mammography, and the influence of increasing experience on performance was examined separately for radiologists with and those without fellowship training in breast imaging, taking into account case-mix and radiologist-level differences. RESULTS: A total of 1 599 610 mammograms were interpreted during the study period. Performance for radiologists without fellowship training improved most during their 1st 3 years of clinical practice, when the odds of a false-positive reading dropped 11%-15% per year (P < .015) with no associated decrease in sensitivity (P > .89). The number of women recalled per breast cancer detected decreased from 33 for radiologists in their 1st year of practice to 24 for radiologists with 3 years of experience to 19 for radiologists with 20 years of experience. Radiologists with fellowship training in breast imaging experienced no learning curve and reached desirable goals during their 1st year of practice. CONCLUSION: Radiologists' interpretations of screening mammograms improve during their first few years of practice and continue to improve throughout much of their careers. Additional residency training and targeted continuing medical education may help reduce the number of work-ups of benign lesions while maintaining high cancer detection rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2533090070

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 137

Metadata

Authors
Miglioretti, D. L., Gard, C. C., Carney, P. A., Onega, T. L., Buist, D. S. M., Sickles, E. A., Kerlikowske, K., Rosenberg, R. D., Yankaskas, B. C., Geller, B. M., & Elmore, J. G.
Venue
Radiology
Published
2009-12
Volume
253
Issue
3
Pages
632-640
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2006494851
Cited by
137
References
0
FWCI
4.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: When Radiologists Perform Best: The Learning Curve in Screening Mammogram Interpretation. https://app.cochat.ai/papers/10.1148/radiol.2533090070
The paper
Miglioretti, D. L., Gard, C. C., Carney, P. A., Onega, T. L., Buist, D. S. M., Sickles, E. A., Kerlikowske, K., Rosenberg, R. D., Yankaskas, B. C., Geller, B. M., & Elmore, J. G. (2009). When Radiologists Perform Best: The Learning Curve in Screening Mammogram Interpretation. Radiology. https://doi.org/10.1148/radiol.2533090070

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.