Orientation of tendons in the magnetic field and its effect on T2 relaxation times.
The DOI matches its Crossref record.
Abstract
In vitro studies of spin-spin relaxation times of the protons or hydrogen nuclei which make up the tendon demonstrated significant dependence of T2 on orientation at physiological levels of hydration. T2 varied from approximately 250 mu sec. with the tendon aligned with the magnetic field to 22 msec. at an angle of 55 degrees or 125 degrees and 4 msec. at deviations of +/- 15 degrees from 55 degrees and 125 degrees. 55 degrees and 125 degrees are the so-called "magic angles" at which 3 cos2 theta - 1 = 0. As a result, the signal from human tendons in vivo will depend on their orientation; however, T2 is generally short enough that the signal intensity will approach 0 in MR images regardless of the orientation of the tendons, thereby preventing this phenomenon from being observed in most studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Benjamin, M., Toumi, H., Ralphs, J. R., Bydder, G., Best, T. M., & Milz, S. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00540.x · Cited by 898
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
Anisotropy of NMR properties of tissues
Henkelman, R. M., Stanisz, G. J., Kim, J. K., & Bronskill, M. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320508 · Cited by 424
Magnetic Resonance Imaging of Short T2 Components in Tissue
Gatehouse, P. D., & Bydder, G. M. (2003) · Clinical Radiology · doi:10.1053/crad.2003.1157 · Cited by 317
Magic-Angle Effect in Magnetic Resonance Imaging of Articular Cartilage: A Review
XIA, Y. (2000) · Investigative Radiology · doi:10.1097/00004424-200010000-00007 · Cited by 300
UTE imaging in the musculoskeletal system
Chang, E. Y., Du, J., & Chung, C. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24713 · Cited by 276
Relaxation anisotropy in cartilage by NMR microscopy (μMRI) at 14‐μm resolution
Xia, Y. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390612 · Cited by 248
Zalesskiy, S. S., Danieli, E., Blümich, B., & Ananikov, V. P. (2014) · Chemical Reviews · doi:10.1021/cr400063g · Cited by 232
Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
Tyler, D. J., Robson, M. D., Henkelman, R. M., Young, I. R., & Bydder, G. M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20851 · Cited by 223
Duyn, J. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.013 · Cited by 95
“Note that the above mechanism for T2 orientation dependence is different than that underlying the orientation dependent T2 that has been observed in skeletal muscle [102], peripheral nerve [103], and cartilage [104], which has been attributed to dipole–dipole interactions of oriented water molecules.”
Background
Metadata
- Authors
- Fullerton, G. D., Cameron, I. L., & Ord, V. A.
- Venue
- Radiology
- Published
- 1985-05
- Volume
- 155
- Issue
- 2
- Pages
- 433-435
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2065297510
- Cited by
- 250
- References
- 0
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.