The DOI matches its Crossref record.
Septate versus bicornuate uteri: errors in imaging diagnosis.
Abstract
Since two müllerian defects, the septate and bicornuate uteri, are no longer repaired by means of the same operative approach, an accurate preoperative diagnosis of these anomalies is now critical. A septum can be removed by means of hysteroscopic metroplasty. However, repair of a bicornuate uterus still requires abdominal surgery. Hysterosalpingography (HSG) has been the primary diagnostic modality for müllerian defects. On the basis of 63 patients, HSG findings alone, as interpreted by the radiologist, had a diagnostic accuracy of 55%. When this was supplemented with a gynecologic evaluation, the diagnostic accuracy improved to only 62.5%. However, when a diagnostic protocol that include ultrasound (US) examination with HSG was used for evaluating müllerian defects, the diagnostic accuracy improved to 90%, with all errors being noncritical. Therefore, it is concluded that HSG alone is not adequate to make the distinction between a septate and a bicornuate uterus unless the angle of divergence of two straight uterine cavities is 75 degrees or less, indicating a septate uterus. Luteal-phase US is frequently necessary to distinguish between these anomalies or to diagnose them in combination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chan, Y. Y., Jayaprakasan, K., Zamora, J., Thornton, J. G., Raine-Fenning, N., & Coomarasamy, A. (2011) · Human Reproduction Update · doi:10.1093/humupd/dmr028 · Cited by 758
The septate uterus: a review of management and reproductive outcome
Homer, H. A., Li, T.-C., & Cooke, I. D. (2000) · Fertility and Sterility · doi:10.1016/s0015-0282(99)00480-x · Cited by 715
Saravelos, S. H., Cocksedge, K. A., & Li, T.-C. (2008) · Human Reproduction Update · doi:10.1093/humupd/dmn018 · Cited by 683
Müllerian Duct Anomalies: Imaging and Clinical Issues
Troiano, R. N., & McCarthy, S. M. (2004) · Radiology · doi:10.1148/radiol.2331020777 · Cited by 622
Taylor, E., & Gomel, V. (2008) · Fertility and Sterility · doi:10.1016/j.fertnstert.2007.09.069 · Cited by 384
Metadata
- Authors
- Reuter, K. L., Daly, D. C., & Cohen, S. M.
- Venue
- Radiology
- Published
- 1989-09
- Volume
- 172
- Issue
- 3
- Pages
- 749-752
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2100727913
- Cited by
- 161
- References
- 0
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Septate versus bicornuate uteri: errors in imaging diagnosis. https://app.cochat.ai/papers/10.1148/radiology.172.3.2528160
- The paper
- Reuter, K. L., Daly, D. C., & Cohen, S. M. (1989). Septate versus bicornuate uteri: errors in imaging diagnosis. Radiology. https://doi.org/10.1148/radiology.172.3.2528160
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.