The DOI matches its Crossref record.
Adaptive technique for high-definition MR imaging of moving structures.
Abstract
An adaptive technique for measuring and correcting the effects of patient motion during magnetic resonance image acquisition was developed and tested. A set of algorithms that can reverse the effects of object displacements and phase shifts was used. These algorithms essentially transfer the frame of reference of the image reconstruction from the static frame of the imager couch to the moving "visceral frame." An accurate record of tissue motion during image acquisition is required. To achieve this, the authors used specially encoded "navigator" echoes that are interleaved with the imaging sequence. Postprocessing of the navigator echo data provides a highly detailed record of the displacements and phase shifts that occur during imaging. Phantom studies demonstrated that the technique can directly correct image degradation caused by motion. In contrast to conventional artifact reduction techniques, such as ordered phase encoding and gradient moment nulling, this new method has a unique capacity to reduce motion unsharpness. Preliminary in vivo studies have demonstrated that the technique can markedly improve images degraded by voluntary motion and shows promise for addressing the problem of respiratory motion in thoracoabdominal imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alexander-Bloch, A., Clasen, L., Stockman, M., Ronan, L., Lalonde, F., Giedd, J., & Raznahan, A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23180 · Cited by 178
3D Whole Heart Imaging for Congenital Heart Disease
Greil, G., Tandon, A. (., Silva Vieira, M., & Hussain, T. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00036 · Cited by 50
Svedin, B. T., Payne, A., & Parker, D. L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25860 · Cited by 30
Metadata
- Authors
- Ehman, R. L., & Felmlee, J. P.
- Venue
- Radiology
- Published
- 1989-10
- Volume
- 173
- Issue
- 1
- Pages
- 255-263
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2021396393
- Cited by
- 801
- References
- 0
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.