Polyclonal human immunoglobulin G labeled with polymeric iron oxide: antibody MR imaging.
The DOI matches its Crossref record.
Abstract
Human polyclonal immunoglobulin (Ig) G was attached to a monocrystalline iron oxide nanocompound (MION), a small superparamagnetic probe developed for receptor and antibody magnetic resonance (MR) imaging. The resulting complex, MION-IgG, had a slightly negative surface charge, a molecular weight of 150-180 kDa, and 0.36 microgram of IgG attached per milligram of iron. After intravenous administration of MION-IgG to normal rats, most of the compound localized in liver, spleen, and bone marrow. In an animal model of myositis, MION-IgG caused reduced signal intensity (most apparent on T2-weighted spin-echo and gradient-echo images) at the site of inflammation. No change in signal intensity existed after an injection of unlabeled MION. Site-specific localization of MION-IgG was corroborated with scintigraphic imaging with indium-111 IgG and MION-In-111-IgG and was confirmed histologically with iron staining. These results indicate that antibody MR imaging is feasible in vivo. Target-specific and antibody MR imaging could be easily extended to other applications, including detection of cancer, infarction, and degenerative diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,594
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Magnetic nanoparticle design for medical diagnosis and therapy
Mornet, S., Vasseur, S., Grasset, F., & Duguet, E. (2004) · Journal of Materials Chemistry · doi:10.1039/b402025a · Cited by 1,745
Metadata
- Authors
- Weissleder, R., Lee, A. S., Fischman, A. J., Reimer, P., Shen, T., Wilkinson, R., Callahan, R. J., & Brady, T. J.
- Venue
- Radiology
- Published
- 1991-10
- Volume
- 181
- Issue
- 1
- Pages
- 245-249
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2016524717
- Cited by
- 153
- References
- 0
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyclonal human immunoglobulin G labeled with polymeric iron oxide: antibody MR imaging. https://app.cochat.ai/papers/10.1148/radiology.181.1.1887040
- The paper
- Weissleder, R., Lee, A. S., Fischman, A. J., Reimer, P., Shen, T., Wilkinson, R., Callahan, R. J., & Brady, T. J. (1991). Polyclonal human immunoglobulin G labeled with polymeric iron oxide: antibody MR imaging. Radiology. https://doi.org/10.1148/radiology.181.1.1887040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.