The DOI matches its Crossref record.
Coronary arteries: breath-hold MR angiography.
Abstract
The authors describe a method for performance of ultrafast magnetic resonance (MR) angiography of coronary arteries with a standard clinical MR system and a body coil. Each image was obtained within a single breath hold by using an electrocardiography-gated, segmented, ultrafast, gradient-echo pulse sequence with an incremental excitation flip angle for the eight phase-encoding steps acquired per segment. By using overlapping 4-mm-thick sections, the coronary arteries were routinely depicted from the coronary ostia distally at MR in healthy subjects. Ultrafast MR angiography of the coronary arteries is feasible with use of a standard body coil. This technique offers considerable potential as an investigational tool and, with further development, may become a clinically useful imaging application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320
Self-citationStuber, M., Botnar, R. M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au50579 · Cited by 256
Self-citation3D Whole Heart Imaging for Congenital Heart Disease
Greil, G., Tandon, A. (., Silva Vieira, M., & Hussain, T. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00036 · Cited by 50
Metadata
- Authors
- Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S.
- Venue
- Radiology
- Published
- 1991-12
- Volume
- 181
- Issue
- 3
- Pages
- 641-643
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2036951583
- Cited by
- 361
- References
- 0
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary arteries: breath-hold MR angiography. https://app.cochat.ai/papers/10.1148/radiology.181.3.1947074
- The paper
- Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991). Coronary arteries: breath-hold MR angiography. Radiology. https://doi.org/10.1148/radiology.181.3.1947074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.