Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record.

Three-dimensional gradient-echo MR imaging of the knee: comparison with arthroscopy in 100 patients.

Heron, C W, Calvert, P T · 1992 · Radiology

Abstract

To compare the findings on magnetic resonance (MR) images of the knee obtained with a three-dimensional gradient-echo (GRE) sequence with findings at arthroscopy, the menisci, cruciate ligaments, and hyaline cartilage were assessed in 100 patients. At MR imaging (performed by means of fast imaging with steady-state precession) and arthroscopy, the menisci (n = 200) and areas of hyaline cartilage (n = 500) were assigned grades of zero (normal) to three (greatest abnormality). The cruciate ligaments were considered intact, partially torn, or completely torn. The sensitivity of MR imaging in diagnosis of meniscal tears seen at arthroscopy was 97% and the specificity, 94%. For complete tears of the anterior cruciate ligament, the sensitivity was 92% and specificity, 96%. In the posterior cruciate ligament, both the sensitivity and specificity were 100%. Good correlation existed between findings at MR imaging and those at arthroscopy in assessment of focal thinning and full-thickness loss of hyaline cartilage, but arthroscopy enabled superior visualization of minor fissuring. Three-dimensional GRE MR imaging enables accurate assessment of the articular cartilage of the knee. The evaluation of meniscal tears and the cruciate ligaments has a high negative predictive value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.183.3.1584944

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Heron, C. W., & Calvert, P. T.
Venue
Radiology
Published
1992-06
Volume
183
Issue
3
Pages
839-844
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1969111814
Cited by
199
References
0
FWCI
10.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-dimensional gradient-echo MR imaging of the knee: comparison with arthroscopy in 100 patients. https://app.cochat.ai/papers/10.1148/radiology.183.3.1584944
The paper
Heron, C. W., & Calvert, P. T. (1992). Three-dimensional gradient-echo MR imaging of the knee: comparison with arthroscopy in 100 patients. Radiology. https://doi.org/10.1148/radiology.183.3.1584944

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.