The DOI matches its Crossref record.
Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging.
Abstract
The interstudy reproducibility of velocity-encoded cine (VEC) magnetic resonance (MR) imaging for quantification of regurgitant volume (RV) and regurgitant fraction (RF) was studied in 10 patients with chronic aortic regurgitation. Each patient underwent two VEC MR imaging studies. RV and RF were measured on the aortic flow curve by quantifying antegrade and retrograde flow per cardiac cycle. VEC MR imaging measurements for RV and RF correlated closely with volumetric measurements for both studies (r greater than .97). Interstudy reproducibility for VEC MR imaging measurement of RV and RF was high (r greater than .97), and the interstudy variability for VEC MR imaging measurements was low. These results demonstrate a high accuracy of VEC MR imaging for measurement of RV and RF in patients with chronic aortic regurgitation. The level of interstudy reproducibility of VEC MR imaging for quantitative assessment of RV and RF indicates the potential of this technique for follow-up and monitoring of response to therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
Metadata
- Authors
- Dulce, M. C., Mostbeck, G. H., O'Sullivan, M., Cheitlin, M., Caputo, G. R., & Higgins, C. B.
- Venue
- Radiology
- Published
- 1992-10
- Volume
- 185
- Issue
- 1
- Pages
- 235-240
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2132943559
- Cited by
- 206
- References
- 0
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging. https://app.cochat.ai/papers/10.1148/radiology.185.1.1523315
- The paper
- Dulce, M. C., Mostbeck, G. H., O'Sullivan, M., Cheitlin, M., Caputo, G. R., & Higgins, C. B. (1992). Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging. Radiology. https://doi.org/10.1148/radiology.185.1.1523315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.