The DOI matches its Crossref record.
Brain parenchyma motion: measurement with cine echo-planar MR imaging.
Abstract
With echo-planar magnetic resonance (MR) imaging, the authors measured the intrinsic pulsatile motion of brain parenchyma. Phase-sensitive, electrocardiography-gated, two-dimensional cine images were acquired throughout the cardiac cycle by using a spin-echo, blipped echo-planar MR pulse sequence. Transverse and coronal planes were obtained in 14 healthy volunteers. Corrections were made for gross head motion. Brain motion consisted of a rapid displacement in systole, with a slow diastolic recovery. The motion occurred chiefly in the cephalocaudal and lateral directions; the anteroposterior motions were relatively small. Cephalocaudal velocities increase with proximity to the foramen magnum. The lateral motion is mainly a compressive motion of the thalami. Brain parenchymal velocities were as high as 2 mm/sec caudally in the brain stem and 1.5 mm/sec medially in the thalami. Net parenchymal excursions were at most 0.5 mm. Phase-based echo-planar velocity measurements agreed well with echo-planar Fourier velocity zeugmatography measurements and were consistent with reported values. Velocity mapping with echo-planar imaging offers a rapid and flexible method of assessing the pulsation velocities of the human brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Basic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Optimization of Transcutaneous Vagus Nerve Stimulation Using Functional MRI
Yakunina, N., Kim, S. S., & Nam, E.-C. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12541 · Cited by 494
Kiviniemi, V., Wang, X., Korhonen, V., Keinänen, T., Tuovinen, T., Autio, J., LeVan, P., Keilholz, S., Zang, Y.-F., Hennig, J., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x15622047 · Cited by 453
Metadata
- Authors
- Poncelet, B. P., Wedeen, V. J., Weisskoff, R. M., & Cohen, M. S.
- Venue
- Radiology
- Published
- 1992-12
- Volume
- 185
- Issue
- 3
- Pages
- 645-651
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1983913144
- Cited by
- 285
- References
- 0
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Brain parenchyma motion: measurement with cine echo-planar MR imaging. https://app.cochat.ai/papers/10.1148/radiology.185.3.1438740
- The paper
- Poncelet, B. P., Wedeen, V. J., Weisskoff, R. M., & Cohen, M. S. (1992). Brain parenchyma motion: measurement with cine echo-planar MR imaging. Radiology. https://doi.org/10.1148/radiology.185.3.1438740
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.