Islet cell tumors: comparison of dynamic contrast-enhanced CT and MR imaging with dynamic gadolinium enhancement and fat suppression.
The DOI matches its Crossref record.
Abstract
Ten patients with 11 islet cell tumors underwent dynamic contrast material-enhanced computed tomography (CT) and magnetic resonance (MR) imaging within a 1-month period. MR imaging depicted all 11 tumors, and CT depicted seven of the 11 tumors. CT did not depict four of seven tumors that measured 2.5 cm in diameter or less. Islet cell tumors had low signal intensity on T1-weighted fat-suppressed MR images, and gastrinomas were best shown with this technique. Two of three insulinomas less than 1.5 cm in diameter were best shown on dynamic contrast-enhanced fast low-angle shot (FLASH) images as uniform areas of high signal intensity. Hepatic metastases were seen in five patients and showed peripheral ringlike enhancement best demonstrated on dynamic gadolinium-enhanced FLASH images. Hepatic lesions were most conspicuous on T2-weighted fat-suppressed spin-echo images. MR imaging with dynamic gadolinium enhancement and fat suppression is a promising tool in the investigation of islet cell tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The diagnosis and medical management of advanced neuroendocrine tumors.
Kaltsas, G. A., Besser, G. M., & Grossman, A. B. (2004) · Endocrine Reviews · doi:10.1210/er.2003-0014 · Cited by 674
Pancreatic tumors: comparison of dual-phase helical CT and endoscopic sonography.
Legmann, P., Vignaux, O., Dousset, B., Baraza, A. J., Palazzo, L., Dumontier, I., Coste, J., Louvel, A., Roseau, G., Couturier, D., et al. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.5.9574609 · Cited by 425
Contrast Agents for MR Imaging of the Liver
Semelka, R. C., & Helmberger, T. K. G. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja2427 · Cited by 337
Self-citationGouya, H., Vignaux, O., Augui, J., Dousset, B., Palazzo, L., Louvel, A., Chaussade, S., & Legmann, P. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.4.1810987 · Cited by 312
Islet Cell Tumor of the Pancreas: Biphasic CT versus MR Imaging in Tumor Detection
Ichikawa, T., Peterson, M. S., Federle, M. P., Baron, R. L., Haradome, H., Kawamori, Y., Nawano, S., & Araki, T. (2000) · Radiology · doi:10.1148/radiology.216.1.r00jl26163 · Cited by 275
Semelka, R. C., Martin, D. R., Balci, C., & Lance, T. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1057 · Cited by 274
Self-citationThoeni, R. F., Mueller-Lisse, U. G., Chan, R., Do, N. K., & Shyn, P. B. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe32483 · Cited by 256
MRI of pancreatic neuroendocrine tumours
Owen, N. J., Sohaib, S. A. A., Peppercorn, P. D., Monson, J. P., Grossman, A. B., Besser, G. M., & Reznek, R. H. (2001) · The British Journal of Radiology · doi:10.1259/bjr.74.886.740968 · Cited by 158
“Most of the tumours imaged in this study exhibited the well documented signal characteristics of low signal on T1 weighted or fat suppressed T1 weighted images and high signal on T2 weighted images [2].”
BackgroundMethodMagnetic Resonance Imaging of Adenocarcinoma of the Pancreas
Vachiranubhap, B., Kim, Y. H., Balci, N. C., & Semelka, R. C. (2009) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181b48392 · Cited by 83
Self-citation
Metadata
- Authors
- Semelka, R. C., Cumming, M. J., Shoenut, J. P., Magro, C. M., Yaffe, C. S., Kroeker, M. A., & Greenberg, H. M.
- Venue
- Radiology
- Published
- 1993-03
- Volume
- 186
- Issue
- 3
- Pages
- 799-802
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2160987971
- Cited by
- 159
- References
- 0
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.