The DOI matches its Crossref record.
MR imaging of the breast with rotating delivery of excitation off resonance: clinical experience with pathologic correlation.
Abstract
An investigative study was undertaken to determine the potential for a new magnetic resonance (MR) imaging technique, RODEO (rotating delivery of excitation off resonance), for use as a diagnostic imaging tool for the breast. The RODEO technique provides fat suppression with T1 weighting and is ideal for gadolinium-enhanced breast imaging. It is a short repetition time, steady-state sequence for high-resolution three-dimensional acquisitions and provides a clinically efficient imaging time of approximately 5 minutes for 128 sections. Imaging findings were correlated with serially sectioned pathologic specimens in 30 breasts with 47 malignant and 27 benign lesions. MR imaging had a sensitivity of 94% and a specificity of 37%. MR imaging depicted additional cancers not seen at mammography in 11 of the 30 patients (37%). The lesions not seen at mammography varied in size from 3 mm to 12 cm. RODEO MR imaging may be used to improve diagnosis of breast cancer in patients with mammographically dense breasts or silicone implants/injections and to stage disease in patients who are candidates for lumpectomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic Resonance Imaging of the Breast Prior to Biopsy
Bluemke, D. A. (2004) · JAMA · doi:10.1001/jama.292.22.2735 · Cited by 513
Breast cancer diagnosis: Imaging techniques and biochemical markers
Jafari, S. H., Saadatpour, Z., Salmaninejad, A., Momeni, F., Mokhtari, M., Nahand, J. S., Rahmati, M., Mirzaei, H., & Kianmehr, M. (2018) · Journal of Cellular Physiology · doi:10.1002/jcp.26379 · Cited by 410
Metadata
- Authors
- Harms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V.
- Venue
- Radiology
- Published
- 1993-05
- Volume
- 187
- Issue
- 2
- Pages
- 493-501
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2010115307
- Cited by
- 634
- References
- 0
- FWCI
- 25.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR imaging of the breast with rotating delivery of excitation off resonance: clinical experience with pathologic correlation. https://app.cochat.ai/papers/10.1148/radiology.187.2.8475297
- The paper
- Harms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V. (1993). MR imaging of the breast with rotating delivery of excitation off resonance: clinical experience with pathologic correlation. Radiology. https://doi.org/10.1148/radiology.187.2.8475297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.