CoChat

Pituitary microadenomas: early enhancement with dynamic CT--implications of arterial blood supply and potential importance.

Bonneville, J F, Cattin, F, Gorczyca, W, Hardy, J · 1993 · Radiology
Cited by 45

The DOI matches its Crossref record.

Abstract

In a search for early contrast medium enhancement, which can indicate the presence of direct arterial supply, a retrospective review of dynamic computed tomographic (CT) scans was performed in 260 patients with a pituitary microadenoma smaller than 10 mm in diameter. Fifty patients underwent examination with dynamic CT for nonendocrinologic disease as a control group to establish the normal pattern of pituitary gland enhancement. One hundred seventy microadenomas (65.4%) displayed the usual dynamic CT pattern (ie, they did not show early enhancement before that of the portal system of the pituitary gland: those pituitary microadenomas appeared less enhanced than the normal pituitary gland during the entire examination). On the other hand, in 90 microadenomas (34.6%), early partial or complete enhancement was seen within the microadenoma before the normal portal enhancement of the gland. Therefore, analysis with dynamic CT yields two groups of pituitary microadenomas separable on the basis of blood supply: those with portal blood supply only and those with partial or predominantly direct arterial blood supply; in theory, the second group avoids hypothalamic control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.187.3.8497646

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bonneville, J. F., Cattin, F., Gorczyca, W., & Hardy, J.
Venue
Radiology
Published
1993-06
Volume
187
Issue
3
Pages
857-861
ISSN
  • 0033-8419
  • 1527-1315
Cited by
45
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.