CoChat

Frameless stereotaxic integration of CT imaging data: accuracy and initial applications.

Zinreich, S J, Tebo, S A, Long, D M, Brem, H, Mattox, D E, Loury, M E, vander Kolk, C A, Koch, W M, Kennedy, D W, Bryan, R N · 1993 · Radiology
Cited by 244

The DOI matches its Crossref record.

Abstract

To evaluate the spatial accuracy of a rapid interactive method of transferring computed tomographic (CT) information between its display on a computer screen to its source (test object, operating field), a multidimensional computer combined with a six-jointed position-sensing mechanical arm was tested with a Plexiglas model consisting of 50 rods of varied height and known location, a plastic replica of the skull, and, subsequently, three patients. The median error value between image and real location was 1-2 mm (P > .95), regardless of the registration target sites. The accuracy, however, increased with the selection of widespread registration points, and 95% of all errors were below 3.70 mm (P > .95). The results compare favorably with the four most commonly used stereotaxic framed units. A misregistration error of 0.3-2.2 mm was found during intraoperative correlation between anatomy on the CT display and actual anatomic location in the operative field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.188.3.8351341

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zinreich, S. J., Tebo, S. A., Long, D. M., Brem, H., Mattox, D. E., Loury, M. E., vander Kolk, C. A., Koch, W. M., Kennedy, D. W., & Bryan, R. N.
Venue
Radiology
Published
1993-09
Volume
188
Issue
3
Pages
735-742
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2105406577
Cited by
244
References
0
FWCI
19.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.