The DOI matches its Crossref record.
MR imaging of the arthritic knee: improved discrimination of cartilage, synovium, and effusion with pulsed saturation transfer and fat-suppressed T1-weighted sequences.
Abstract
PURPOSE: To assess the applicability of three-dimensional (3D) magnetic resonance (MR) imaging with pulsed saturation transfer (ST) or fat saturation in depicting articular structures in arthritic knees. MATERIALS AND METHODS: Eleven patients underwent MR imaging with T1-weighted spin-echo (SE); unenhanced and contrast material-enhanced T2*-weighted 3D gradient-echo with and without on-resonance pulsed ST; and T1-weighted, fat-presaturated 3D gradient-echo techniques. Images with ST were subtracted from those without ST. RESULTS: Both fat-suppressed imaging and ST-subtraction (STS) techniques generated a high contrast-to-noise ratio among cartilage, synovium, effusion, bone, and adipose tissue. Both techniques depicted hypertrophic synovial tissue on unenhanced images; contrast material was necessary to differentiate between synovium and cartilage on STS images. CONCLUSION: 3D MR imaging with fat-suppressed or STS techniques provides good discrimination among articular structures in arthritic knees. Fat-suppressed imaging is faster than STS imaging and offers better contrast between cartilage and synovium. These techniques may improve monitoring of arthritic disease progression and therapeutic response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Whole-Organ Magnetic Resonance Imaging Score (WORMS) of the knee in osteoarthritis
Peterfy, C. G., Guermazi, A., Zaim, S., Tirman, P. F. J., Miaux, Y., White, D., Kothari, M., Lu, Y., Fye, K., Zhao, S., et al. (2004) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2003.11.003 · Cited by 1,540
Self-citationAltman, R., Brandt, K., Hochberg, M., Moskowitz, R., Bellamy, N., Bloch, D. A., Buckwalter, J., Dougados, M., Ehrlich, G., Lequesne, M., et al. (1996) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(05)80101-3 · Cited by 577
Marlovits, S., Striessnig, G., Resinger, C. T., Aldrian, S. M., Vecsei, V., Imhof, H., & Trattnig, S. (2004) · European Journal of Radiology · doi:10.1016/j.ejrad.2004.03.014 · Cited by 416
Disler, D. G., McCauley, T. R., Kelman, C. G., Fuchs, M. D., Ratner, L. M., Wirth, C. R., & Hospodar, P. P. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.167.1.8659356 · Cited by 392
Magnetization transfer imaging: practical aspects and clinical applications.
Wolff, S. D., & Balaban, R. S. (1994) · Radiology · doi:10.1148/radiology.192.3.8058919 · Cited by 291
Metadata
- Authors
- Peterfy, C. G., Majumdar, S., Lang, P., van Dijke, C. F., Sack, K., & Genant, H. K.
- Venue
- Radiology
- Published
- 1994-05
- Volume
- 191
- Issue
- 2
- Pages
- 413-419
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2044713368
- Cited by
- 184
- References
- 0
- FWCI
- 18.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR imaging of the arthritic knee: improved discrimination of cartilage, synovium, and effusion with pulsed saturation transfer and fat-suppressed T1-weighted sequences. https://app.cochat.ai/papers/10.1148/radiology.191.2.8153315
- The paper
- Peterfy, C. G., Majumdar, S., Lang, P., van Dijke, C. F., Sack, K., & Genant, H. K. (1994). MR imaging of the arthritic knee: improved discrimination of cartilage, synovium, and effusion with pulsed saturation transfer and fat-suppressed T1-weighted sequences. Radiology. https://doi.org/10.1148/radiology.191.2.8153315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.