Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain.
Abstract
PURPOSE: To demonstrate the feasibility of three-dimensional echo-planar spectroscopic imaging (EPSI) at short echo time (13 msec) with a conventional clinical imager in the human brain. MATERIALS AND METHODS: Periodic inversions of a readout gradient were used during data acquisition to simultaneously encode chemical shift and one spatial dimension in one excitation. Aliasing artifacts were avoided with a modified acquisition-and-processing method based on oversampling. A double outer-volume suppression technique that adapts to the ovoid brain shape was used to strongly reduce extracranial lipid resonances. RESULTS: Three-dimensional spatial encoding in vivo of eight sections with 32 x 32 voxels each (0.75 cm3) was performed in 34 minutes with four signal averages. The spectral resolution and signal-to-noise ratio (S/N) of resonances of inositol, choline, creatine, glutamate and glutamine, and N-acetyl aspartate were consistent with those previously recorded with conventional phase encoding. CONCLUSION: EPSI substantially reduces acquisition time for three-dimensional spatial encoding and yields a spectral quality similar to that obtained with conventional techniques without affecting the S/N per unit time and unit volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Self-citationEnhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
Posse, S., Wiese, S., Gembris, D., Mathiak, K., Kessler, C., Grosse-Ruyken, M.-L., Elghahwagi, B., Richards, T., Dager, S. R., & Kiselev, V. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<87::aid-mrm13>3.0.co;2-o · Cited by 388
Self-citationIn vivo magnetic resonance spectroscopy: basic methodology and clinical applications
van der Graaf, M. (2010) · European Biophysics Journal · doi:10.1007/s00249-009-0517-y · Cited by 275
Metadata
- Authors
- Posse, S., DeCarli, C., & Le Bihan, D.
- Venue
- Radiology
- Published
- 1994-09
- Volume
- 192
- Issue
- 3
- Pages
- 733-738
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1978566250
- Cited by
- 190
- References
- 0
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain. https://app.cochat.ai/papers/10.1148/radiology.192.3.8058941
- The paper
- Posse, S., DeCarli, C., & Le Bihan, D. (1994). Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain. Radiology. https://doi.org/10.1148/radiology.192.3.8058941
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.