AMI-227-enhanced MR lymphography: usefulness for differentiating reactive from tumor-bearing lymph nodes.
The DOI matches its Crossref record.
Abstract
PURPOSE: To determine the value of magnetic resonance (MR) lymphography enhanced with AMI-227, a superparamagnetic reticuloendothelial-system-specific contrast agent, to distinguish normal and reactive from tumor-bearing lymph nodes. MATERIALS AND METHODS: Mature male Copenhagen rats were inoculated with cell suspensions of R3327-MATLyLu rat prostate carcinoma (n = 16) or Complete Freund Adjuvant (n = 15) to generate ipsilateral popliteal lymph node metastases or lymphadenitis. At 12-14 days after inoculation, T1- and T2-weighted MR images of bilateral popliteal areas were obtained before and 24 hours after administration of AMI-227 (dose, 30 mumol Fe/kg). The contralateral popliteal nodes served as controls. Contrast-to-noise ratios (C/Ns) between the nodes and adjacent muscle were calculated in pre- and postcontrast images. Subsequently, bilateral popliteal nodes were excised. RESULTS: AMI-227 resulted in decreased C/N in reactive nodes (T1-weighted, -186% +/- 90% [standard deviation]; T2-weighted, -205% +/- 96%) and normal nodes (n = 7) (T1-weighted, -306% +/- 82; T2-weighted, -350% +/- 96). C/N remained unchanged or increased (T1-weighted, 88% +/- 92; T2-weighted, 306% +/- 256) (P < .05). CONCLUSION: Differences in AMI-227 uptake at MR imaging may help differentiate tumor-bearing from nontumor-bearing nodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Ruehm, S. G., Corot, C., Vogt, P., Kolb, S., & Debatin, J. F. (2001) · Circulation · doi:10.1161/01.cir.103.3.415 · Cited by 599
Lymphedema: classification, diagnosis and therapy
Szuba, A., & Rockson, S. G. (1998) · Vascular Medicine · doi:10.1177/1358836x9800300209 · Cited by 446
Rockall, A. G., Sohaib, S. A., Harisinghani, M. G., Babar, S. A., Singh, N., Jeyarajah, A. R., Oram, D. H., Jacobs, I. J., Shepherd, J. H., & Reznek, R. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.07.166 · Cited by 342
Bourrinet, P., Bengele, H. H., Bonnemain, B., Dencausse, A., Idee, J.-M., Jacobs, P. M., & Lewis, J. M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000197669.80475.dd · Cited by 339
Metadata
- Authors
- Vassallo, P., Matei, C., Heston, W. D., McLachlan, S. J., Koutcher, J. A., & Castellino, R. A.
- Venue
- Radiology
- Published
- 1994-11
- Volume
- 193
- Issue
- 2
- Pages
- 501-506
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1977314859
- Cited by
- 143
- References
- 0
- FWCI
- 6.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AMI-227-enhanced MR lymphography: usefulness for differentiating reactive from tumor-bearing lymph nodes. https://app.cochat.ai/papers/10.1148/radiology.193.2.7972768
- The paper
- Vassallo, P., Matei, C., Heston, W. D., McLachlan, S. J., Koutcher, J. A., & Castellino, R. A. (1994). AMI-227-enhanced MR lymphography: usefulness for differentiating reactive from tumor-bearing lymph nodes. Radiology. https://doi.org/10.1148/radiology.193.2.7972768
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.