Pancreatic receptors: initial feasibility studies with a targeted contrast agent for MR imaging.
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate cholecystokinin (CCK) as a target-specific vector for magnetic resonance (MR) receptor imaging of rat pancreas. MATERIALS AND METHODS: Monocrystalline iron oxide (MION) was labeled with CCK by noncovalent attachment. Receptor specificity of the conjugate was determined with competitive binding studies. Pharmacologic determinations were blood half-lives, biodistribution, time responses, dose responses, and limited toxicity. RESULTS: Specific cell binding of MION-20-CCK was saturable and inhibitable by a CCK antagonist. Blood half-life of MION-20-CCK was 20 minutes, which was shorter than that of unlabeled MION. Biodistribution studies showed a statistically significant decrease in relaxation times in pancreatic tissues from 42.7 msec +/- 2.0 to 33.8 msec +/- 1.4 (P < or = .05) but not in tumor after administration of MION-20-CCK. The half-life of MION-20-CCK in the pancreas was 3 weeks; no signs of toxicity were shown at the level tested. CONCLUSION: Target-specific MR imaging of pancreatic receptors is feasible. Additional studies are necessary to perfect binding strategies, optimize preparations, and scale up synthesis for imaging in other species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Mahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Metadata
- Authors
- Reimer, P., Weissleder, R., Shen, T., Knoefel, W. T., & Brady, T. J.
- Venue
- Radiology
- Published
- 1994-11
- Volume
- 193
- Issue
- 2
- Pages
- 527-531
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2005628251
- Cited by
- 53
- References
- 0
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pancreatic receptors: initial feasibility studies with a targeted contrast agent for MR imaging. https://app.cochat.ai/papers/10.1148/radiology.193.2.7972773
- The paper
- Reimer, P., Weissleder, R., Shen, T., Knoefel, W. T., & Brady, T. J. (1994). Pancreatic receptors: initial feasibility studies with a targeted contrast agent for MR imaging. Radiology. https://doi.org/10.1148/radiology.193.2.7972773
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.