Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record.

Uneven fatty replacement of the pancreas: evaluation with CT.

Matsumoto, S, Mori, H, Miyake, H, Takaki, H, Maeda, T, Yamada, Y, Oga, M · 1995 · Radiology

Abstract

PURPOSE: To determine the computed tomographic (CT) features of uneven fatty replacement of the pancreas and clarify their radiologic and clinical importance. MATERIALS AND METHODS: CT scans from 80 patients with uneven fatty replacement of the pancreas were reviewed. Uneven fatty replacement of the pancreas was classified into two types. In type 1, the posterior aspect of the head of the pancreas was spared from intense fatty replacement. In type 2, the focal area around the common bile duct (CBD) was spared from fatty replacement. Each type was divided into two subgroups on the basis of whether the body and tail of the pancreas showed intense fatty replacement (type a = negative for intense fatty replacement, type b = positive for intense fatty replacement). Findings from endoscopic retrograde cholangiopancreatography performed in five patients, histopathologic examination in one patient, and clinical examination in all 80 patients were also evaluated. RESULTS: Twenty-eight patients (35%) had type 1a replacement, 29 (36%) had type 1b replacement, nine (11%) had type 2a replacement, and 14 (18%) had type 2b replacement. In all patients, the anterior aspect of the head of the pancreas showed distinctly lower attenuation at CT. CONCLUSION: Fatty replacement is more severe in the anterior aspect of the head of the pancreas. The posterior aspect of the head of the pancreas and the area around the CBD tended to be spared.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.194.2.7824726

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Matsumoto, S., Mori, H., Miyake, H., Takaki, H., Maeda, T., Yamada, Y., & Oga, M.
Venue
Radiology
Published
1995-02
Volume
194
Issue
2
Pages
453-458
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2063397136
Cited by
159
References
0
FWCI
0.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Uneven fatty replacement of the pancreas: evaluation with CT. https://app.cochat.ai/papers/10.1148/radiology.194.2.7824726
The paper
Matsumoto, S., Mori, H., Miyake, H., Takaki, H., Maeda, T., Yamada, Y., & Oga, M. (1995). Uneven fatty replacement of the pancreas: evaluation with CT. Radiology. https://doi.org/10.1148/radiology.194.2.7824726

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.