Mechanism of satisfaction of search: eye position recordings in the reading of chest radiographs.
The DOI matches its Crossref record.
Abstract
PURPOSE: To use the eye position recordings of observers as they read chest images to advance understanding of the mechanism of "satisfaction of search," a phenomenon in which the detection of one abnormality interferes with the detection of other abnormalities. MATERIALS AND METHODS: Eight radiologists examined chest images that contained simulated pulmonary nodules and native abnormalities. Accuracy in detecting nodules and native abnormalities and eye position, gaze duration, and total search time were recorded. RESULTS: Nodule detectability was lower on native abnormality-containing images than it was on normal images (P < .005). Native-abnormality detectability was not negatively affected by the nodules. Most missed nodules were fixated; only those on images without native abnormalities, however, received prolonged visual attention. CONCLUSION: The satisfaction of search phenomenon is an important source of error in the detection of subtle abnormalities but not of obvious abnormalities. Obvious abnormalities capture visual attention and decrease vigilance for more subtle abnormalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rare items often missed in visual searches
Wolfe, J. M., Horowitz, T. S., & Kenner, N. M. (2005) · Nature · doi:10.1038/435439a · Cited by 518
Low target prevalence is a stubborn source of errors in visual search tasks.
Wolfe, J. M., Horowitz, T. S., Van Wert, M. J., Kenner, N. M., Place, S. S., & Kibbi, N. (2007) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.136.4.623 · Cited by 418
Observer studies involving detection and localization: Modeling, analysis, and validation
Chakraborty, D. P., & Berbaum, K. S. (2004) · Medical Physics · doi:10.1118/1.1769352 · Cited by 351
Sim, Y., Chung, M. J., Kotter, E., Yune, S., Kim, M., Do, S., Han, K., Kim, H., Yang, S., Lee, D.-J., et al. (2020) · Radiology · doi:10.1148/radiol.2019182465 · Cited by 248
A review of eye tracking for understanding and improving diagnostic interpretation
Brunyé, T. T., Drew, T., Weaver, D. L., & Elmore, J. G. (2019) · Cognitive Research: Principles and Implications · doi:10.1186/s41235-019-0159-2 · Cited by 227
Spectrum of diagnostic errors in radiology
Pinto, A. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.377 · Cited by 202
Missed lung cancer: when, where, and why?
Ciello, A. D., Franchi, P., Contegiacomo, A., Cicchetti, G., Bonomo, L., & Larici, A. R. (2017) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2016.16187 · Cited by 187
Wolfe, J. M., Brunelli, D. N., Rubinstein, J., & Horowitz, T. S. (2013) · Journal of Vision · doi:10.1167/13.3.33 · Cited by 161
Pitfalls in Chest Radiographic Interpretation: Blind Spots
de Groot, P. M., Carter, B. W., Abbott, G. F., & Wu, C. C. (2015) · Seminars in Roentgenology · doi:10.1053/j.ro.2015.01.008 · Cited by 44
Common Errors and Pitfalls in Interpretation of the Adult Chest Radiograph
Kanne, J. P., Thoongsuwan, N., & Stern, E. J. (2005) · Clinical Pulmonary Medicine · doi:10.1097/01.cpm.0000156704.33941.e2 · Cited by 17
“viewer ceases to find other often important abnormalities after detecting an obvious finding.(1)”
Background
Metadata
- Authors
- Samuel, S., Kundel, H. L., Nodine, C. F., & Toto, L. C.
- Venue
- Radiology
- Published
- 1995-03
- Volume
- 194
- Issue
- 3
- Pages
- 895-902
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2117857977
- Cited by
- 168
- References
- 0
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.