The DOI matches its Crossref record.
Potentially resectable pancreatic adenocarcinoma: spiral CT assessment with surgical and pathologic correlation.
Abstract
PURPOSE: To evaluate the accuracy of spiral computed tomography (CT) in assessing the resectability of small pancreatic ductal adenocarcinoma and to correlate the CT findings with histopathologic and surgical findings. MATERIALS AND METHODS: Spiral CT scans obtained in 64 patients who underwent surgery for potentially resectable pancreatic adenocarcinoma were prospectively assessed for tumor resectability. CT findings were correlated with surgically assessed extent of tumor and pathologic findings. RESULTS: Fifty-seven (89%) of 64 carcinomas were detected with spiral CT. Twenty-four carcinomas were resectable at surgery and 40 were not. The average size of resectable tumors was 3.1 cm (range, 1.0-7.5 cm). The overall accuracy of spiral CT for assessing resectability was 70%. Of resected tumors, 14 were hypoattenuating compared with the remaining pancreas and 10 were isoattenuating. Eleven tumors showed neointimal proliferation in arterioles at histologic examination. CONCLUSION: Further progress in preoperative staging of pancreatic ductal adenocarcinoma with spiral CT should be directed toward improving detection of small pancreatic tumors and assessment of early metastatic disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Isoattenuating Pancreatic Adenocarcinoma at Multi–Detector Row CT: Secondary Signs
Prokesch, R. W., Chow, L. C., Beaulieu, C. F., Bammer, R., & Jeffrey, R. B. (2002) · Radiology · doi:10.1148/radiol.2243011284 · Cited by 337
McNulty, N. J., Francis, I. R., Platt, J. F., Cohan, R. H., Korobkin, M., & Gebremariam, A. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl1897 · Cited by 294
Pawlik, T. M., Laheru, D., Hruban, R. H., Coleman, J., Wolfgang, C. L., Campbell, K., Ali, S., Fishman, E. K., Schulick, R. D., Herman, J. M., et al. (2008) · Annals of Surgical Oncology · doi:10.1245/s10434-008-9929-7 · Cited by 273
Self-citationBipat, S., Phoa, S. S. K. S., van Delden, O. M., Bossuyt, P. M. M., Gouma, D. J., Lam??ris, J. S., & Stoker, J. (2005) · Journal of Computer Assisted Tomography · doi:10.1097/01.rct.0000164513.23407.b3 · Cited by 272
Yoon, S. H., Lee, J. M., Cho, J. Y., Lee, K. B., Kim, J. E., Moon, S. K., Kim, S. J., Baek, J. H., Kim, S. H., Kim, S. H., et al. (2011) · Radiology · doi:10.1148/radiol.11101133 · Cited by 257
Metadata
- Authors
- Bluemke, D. A., Cameron, J. L., Hruban, R. H., Pitt, H. A., Siegelman, S. S., Soyer, P., & Fishman, E. K.
- Venue
- Radiology
- Published
- 1995-11
- Volume
- 197
- Issue
- 2
- Pages
- 381-385
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2008043160
- Cited by
- 291
- References
- 0
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Potentially resectable pancreatic adenocarcinoma: spiral CT assessment with surgical and pathologic correlation. https://app.cochat.ai/papers/10.1148/radiology.197.2.7480681
- The paper
- Bluemke, D. A., Cameron, J. L., Hruban, R. H., Pitt, H. A., Siegelman, S. S., Soyer, P., & Fishman, E. K. (1995). Potentially resectable pancreatic adenocarcinoma: spiral CT assessment with surgical and pathologic correlation. Radiology. https://doi.org/10.1148/radiology.197.2.7480681
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.