The DOI matches its Crossref record.
Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.
Abstract
PURPOSE: To develop and evaluate a sequence for breath-hold three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography of the abdominal aorta. MATERIALS AND METHODS: In 63 patients, the abdominal aorta and its branches were imaged for 29, 43, or 58 seconds with breath holding. A fast spoiled gradient-echo sequence was used at 1.5 T during infusion of 42 mL of a gadolinium chelate. Correlation with conventional angiography was performed in 19 patients. MR image quality (signal-to-"total" noise ratio [S/N*]) with breath holding was compared with that with free breathing (104 patients). RESULTS: With breath-hold gadolinium-enhanced MR angiography, renal, celiac, and superior mesenteric artery occlusive disease was graded appropriately in 15 of 19 patients, and 10 of 11 accessory renal arteries were depicted correctly. Renal artery branches were visualized in 86 of 95 kidneys on breath-hold images compared with only 84 of 236 kidneys with free breathing (P < .001). Distal renal artery S/N* was 3.1 with breath holding and 2.1 with free breathing (P < .001). CONCLUSION: Breath holding statistically significantly improves three-dimensional gadolinium-enhanced MR angiography of the renal, celiac, and superior mesenteric arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diagnosis of Pulmonary Embolism with Magnetic Resonance Angiography
Meaney, J. F. M., Weg, J. G., Chenevert, T. L., Stafford-Johnson, D., Hamilton, B. H., & Prince, M. R. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705153362004 · Cited by 482
Self-citationNon-occlusive mesenteric ischemia: etiology, diagnosis, and interventional therapy
Trompeter, M., Brazda, T., Remy, C. T., Vestring, T., & Reimer, P. (2002) · European Radiology · doi:10.1007/s00330-001-1220-2 · Cited by 378
Peripheral Artery Disease: Current Insight Into the Disease and Its Diagnosis and Management
Olin, J. W., & Sealove, B. A. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2010.0133 · Cited by 349
Meaney, J. F. M., Prince, M. R., Nostrant, T. T., & Stanley, J. C. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070126 · Cited by 193
Self-citationClinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
Metadata
- Authors
- Prince, M. R., Narasimham, D. L., Stanley, J. C., Chenevert, T. L., Williams, D. M., Marx, M. V., & Cho, K. J.
- Venue
- Radiology
- Published
- 1995-12
- Volume
- 197
- Issue
- 3
- Pages
- 785-792
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2082706576
- Cited by
- 592
- References
- 0
- FWCI
- 44.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. https://app.cochat.ai/papers/10.1148/radiology.197.3.7480757
- The paper
- Prince, M. R., Narasimham, D. L., Stanley, J. C., Chenevert, T. L., Williams, D. M., Marx, M. V., & Cho, K. J. (1995). Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology. https://doi.org/10.1148/radiology.197.3.7480757
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.