Outcome of tunneled hemodialysis catheters placed by radiologists.
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare the outcomes of hemodialysis catheters placed by interventional radiologists with those placed by surgeons. MATERIALS AND METHODS: The outcomes were retrospectively analyzed of 237 hemodialysis catheters placed in 140 patients by a radiology service from January 1991 through December 1992. Follow-up data were available for 222 catheters (94%). Catheter secondary patency and freedom from infection were analyzed statistically and by means of life-table analysis. RESULTS: Pneumothorax occurred after the placement of six catheters (2.5%); in two patients, a chest tube was required for decompression. Other short-term complications included air embolism with no clinical sequelae (two procedures) and prolonged oozing from the tunnel (two procedures). Long-term complications included infection and catheter failure. Infection occurred in 26 patients (18%) with 32 catheters (14%) and resulted in removal of 25 catheters. Ninety-three catheters (42%) failed, and 63 catheters (28%) were removed because of failure. CONCLUSION: Hemodialysis catheters placed by radiologists do not have a higher rate of complications or failure than catheters placed by surgeons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“Administration of intravenous antibiotics alone is not a satisfactory approach, because bloodstream infection recurs in the majority of patients once the course of antibiotics has been completed [101, 106–109].”
BackgroundKDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
III. NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: Update 2000
(2001) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(01)70007-8 · Cited by 806
The hemodialysis catheter conundrum: Hate living with them, but can’t live without them
Schwab, S. J., & Beathard, G. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00512.x · Cited by 388
Dialysis catheter-related bacteremia: Treatment and prophylaxis
Allon, M. (2004) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(04)01078-9 · Cited by 367
Biofilms in Periprosthetic Orthopedic Infections
McConoughey, S. J., Howlin, R., Granger, J. F., Manring, M. M., Calhoun, J. H., Shirtliff, M., Kathju, S., & Stoodley, P. (2014) · Future Microbiology · doi:10.2217/fmb.14.64 · Cited by 343
Current Management of Vascular Access
Allon, M. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00860207 · Cited by 289
Management of hemodialysis catheter-related bacteremia with an adjunctive antibiotic lock solution
Krishnasami, Z., Carlton, D., Bimbo, L., Taylor, M. E., Balkovetz, D. F., Barker, J., & Allon, M. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00201.x · Cited by 278
Management of Bacteremia Associated with Tunneled-Cuffed Hemodialysis Catheters
BEATHARD, G. A. (1999) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1051045 · Cited by 273
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Poole, C. V., Carlton, D., Bimbo, L., & Allon, M. (2004) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfh041 · Cited by 196
“5/1000 patient-days reported from other institutions [1–5].”
BackgroundBacteremia associated with tunneled dialysis catheters: Comparison of two treatment strategies
Tanriover, B., Carlton, D., Saddekni, S., Hamrick, K., Oser, R., Westfall, A. O., & Allon, M. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00067.x · Cited by 185
Quality Improvement Guidelines for Central Venous Access
Dariushnia, S. R., Wallace, M. J., Siddiqi, N. H., Towbin, R. B., Wojak, J. C., Kundu, S., & Cardella, J. F. (2010) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.03.006 · Cited by 185
Metadata
- Authors
- Lund, G. B., Trerotola, S. O., Scheel, P. F., Savader, S. J., Mitchell, S. E., Venbrux, A. C., & Osterman, F. A.
- Venue
- Radiology
- Published
- 1996-02
- Volume
- 198
- Issue
- 2
- Pages
- 467-472
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2062105308
- Cited by
- 174
- References
- 0
- FWCI
- 23.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.