The DOI matches its Crossref record.
Acute mesenteric ischemia: diagnosis with contrast-enhanced CT.
Abstract
PURPOSE: To evaluate the accuracy of dynamic, contrast material-enhanced computed tomography (CT) in the diagnosis of acute mesenteric ischemia. MATERIALS AND METHODS: Reviewers blinded to patient diagnoses retrospectively compared the CT scans in a study group with those in a control group. The study group comprised 39 consecutive patients (23 men, 16 women; aged 55-88 years) with surgically proved acute mesenteric ischemia. The control group comprised 24 patients (13 men, 11 women; aged 50-82 years) with suspected acute mesenteric ischemia that was disproved at surgery. RESULTS: For the diagnosis of acute mesenteric ischemia, each of the following findings had a specificity of more than 95% and a sensitivity of less than 30%: arterial or venous thrombosis, intramural gas, portal venous gas, focal lack of bowel-wall enhancement, and liver or splenic infarcts. When CT was used in the diagnosis of suspected acute mesenteric ischemia, the detection of at least one of these signs resulted in a sensitivity of 64% (25 of 39; confidence interval, 0.49, 0.79), a specificity of 92% (22 of 24; confidence interval, 0.81, 1.00), and an accuracy of 75% (47 of 63; confidence interval, 0.64, 0.86). CONCLUSION: Dynamic, contrast-enhanced CT is a valuable tool in the diagnosis of and determination of prognosis in acute mesenteric ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acute Mesenteric Ischemia: A Clinical Review
Oldenburg, W. A., Lau, L. L., Rodenberg, T. J., Edmonds, H. J., & Burger, C. D. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.10.1054 · Cited by 714
Kirkpatrick, I. D. C., Kroeker, M. A., & Greenberg, H. M. (2003) · Radiology · doi:10.1148/radiol.2291020991 · Cited by 365
Menke, J. (2010) · Radiology · doi:10.1148/radiol.10091938 · Cited by 319
Acute Mesenteric Ischemia: The Challenge of Gastroenterology
Yasuhara, H. (2005) · Surgery Today · doi:10.1007/s00595-004-2924-0 · Cited by 301
Portomesenteric Vein Gas: Pathologic Mechanisms, CT Findings, and Prognosis
Sebastià, C., Quiroga, S., Espin, E., Boyé, R., Alvarez-Castells, A., & Armengol, M. (2000) · RadioGraphics · doi:10.1148/radiographics.20.5.g00se011213 · Cited by 293
Metadata
- Authors
- Taourel, P. G., Deneuville, M., Pradel, J. A., Régent, D., & Bruel, J. M.
- Venue
- Radiology
- Published
- 1996-06
- Volume
- 199
- Issue
- 3
- Pages
- 632-636
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2099727617
- Cited by
- 308
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute mesenteric ischemia: diagnosis with contrast-enhanced CT. https://app.cochat.ai/papers/10.1148/radiology.199.3.8637978
- The paper
- Taourel, P. G., Deneuville, M., Pradel, J. A., Régent, D., & Bruel, J. M. (1996). Acute mesenteric ischemia: diagnosis with contrast-enhanced CT. Radiology. https://doi.org/10.1148/radiology.199.3.8637978
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.