The DOI matches its Crossref record.
Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating.
Abstract
Thin-section, three-dimensional (3D) gradient-echo magnetic resonance imaging of the coronary arteries was performed without and with retrospective respiratory gating in 12 healthy volunteers and one patient. In all examinations, results were improved with gating. In five of seven volunteer examinations, coronary artery delineation on images reconstructed by using the least-squares method for motion detection with navigator echoes was found to be equal to that obtained by using edge detection. Images in five other volunteers covered the entire heart with multiple overlapping 3D slabs. The arteries were segmented from the background and could be viewed from any orientation. The lengths of contiguously visible vessels were as follows: left main coronary artery, 11.5 mm +/- 0.4 (mean +/- standard deviation); left anterior descending branch, 115.9 mm +/- 19.7; left circumflex branch, 97.2 mm +/- 12.5; and right coronary artery, 125.9 mm +/- 18.8. This respiratory gating technique clearly improved depiction of the coronary arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320
Stuber, M., Botnar, R. M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au50579 · Cited by 256
3D Whole Heart Imaging for Congenital Heart Disease
Greil, G., Tandon, A. (., Silva Vieira, M., & Hussain, T. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00036 · Cited by 50
van Geuns, R.-J. M., Oudkerk, M., Rensing, B. J. W. M., Bongaerts, A. H. H., de Bruin, H. G., Wielopolski, P. A., van Ooijen, P., de Feyter, P. J., & Serruys, P. W. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02389-5 · Cited by 24
Metadata
- Authors
- Li, D., Kaushikkar, S., Haacke, E. M., Woodard, P. K., Dhawale, P. J., Kroeker, R. M., Laub, G., Kuginuki, Y., & Gutierrez, F. R.
- Venue
- Radiology
- Published
- 1996-12
- Volume
- 201
- Issue
- 3
- Pages
- 857-863
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2092914618
- Cited by
- 205
- References
- 0
- FWCI
- 19.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. https://app.cochat.ai/papers/10.1148/radiology.201.3.8939242
- The paper
- Li, D., Kaushikkar, S., Haacke, E. M., Woodard, P. K., Dhawale, P. J., Kroeker, R. M., Laub, G., Kuginuki, Y., & Gutierrez, F. R. (1996). Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. Radiology. https://doi.org/10.1148/radiology.201.3.8939242
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.