The DOI matches its Crossref record.
Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists.
Abstract
PURPOSE: To assess the outcome of interventional radiologic placement of tunneled hemodialysis catheters via the right internal jugular vein. MATERIALS AND METHODS: In 194 patients, the catheter was placed via the right internal jugular vein unless thrombosis was present. Real-time ultrasound-guided puncture and fluoroscopic guidance were used. Patients were followed up until catheter removal or death. Outcomes evaluated included infection, thrombosis, and catheter malfunction. RESULTS: In 175 patients, 250 consecutive catheters were placed via the right internal jugular vein with 100% success. All catheters functioned immediately after placement. Procedural complications were limited to clinically unimportant air embolus (n = 2). No instances of pneumothorax, hemothorax, or substantial bleeding complications occurred. Follow-up was available in 173 (99%) patients. Mean and median "catheter duration" were 87 and 56 days, respectively. Catheter-related symptomatic venous thrombosis or stenosis was not observed. The rate of infection was 0.08 per 100 catheter days, and the rate of malfunction that necessitated removal was 0.22 per 100 catheter days. Definite or possible catheter thrombosis that necessitated removal occurred at a rate of 0.16 per 100 catheter days. CONCLUSION: Interventional radiologic placement of tunneled hemodialysis catheters via the right internal jugular vein showed equal or better long-term results than those reported for surgical placement. Interventional radiologic placement should be the method of choice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The hemodialysis catheter conundrum: Hate living with them, but can’t live without them
Schwab, S. J., & Beathard, G. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00512.x · Cited by 388
Venous Thrombosis Associated with the Placement of Peripherally Inserted Central Catheters
Allen, A. W., Megargell, J. L., Brown, D. B., Lynch, F. C., Singh, H., Singh, Y., & Waybill, P. N. (2000) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61307-4 · Cited by 258
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Metadata
- Authors
- Trerotola, S. O., Johnson, M. S., Harris, V. J., Shah, H., Ambrosius, W. T., McKusky, M. A., & Kraus, M. A.
- Venue
- Radiology
- Published
- 1997-05
- Volume
- 203
- Issue
- 2
- Pages
- 489-495
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2127190544
- Cited by
- 192
- References
- 0
- FWCI
- 27.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists. https://app.cochat.ai/papers/10.1148/radiology.203.2.9114110
- The paper
- Trerotola, S. O., Johnson, M. S., Harris, V. J., Shah, H., Ambrosius, W. T., McKusky, M. A., & Kraus, M. A. (1997). Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists. Radiology. https://doi.org/10.1148/radiology.203.2.9114110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.