The DOI matches its Crossref record.
The breast: in-plane x-ray protection during diagnostic thoracic CT--shielding with bismuth radioprotective garments.
Abstract
PURPOSE: To evaluate the ability of thin overlying bismuth radioprotective shielding to reduce the x-ray dose to radiosensitive superficial organs during diagnostic computed tomography (CT). MATERIALS AND METHODS: A variety of patient and phantom studies were performed with four thicknesses of bismuth radioprotective latex over the breast. Dose savings were determined with thermoluminescent dosimeters. A prototype and then a final manufactured radioprotective brassiere was constructed and tested for radiation dose savings to the breast during diagnostic chest CT. Preliminary studies were also performed to evaluate shielding of the thyroid, orbit, and testes. RESULTS: The use of bismuth radioprotective latex saved an average 57% of the radiation dose to the breast from thoracic CT, decreasing the radiation level from an average 2.2 rad (0.022 Gy) to 1.0 rad (0.010 Gy) (P < .001). Preliminary tests of shielding other superficial radiosensitive organs frequently included at diagnostic CT (eyes, thyroid gland, and testes) were performed with the same thickness of overlying bismuth radioprotective latex, with similar results. Radiation to the thyroid gland was reduced by 60% (from 0.0573 to 0.0229 Gy) and radiation to the eye and testes was reduced by 40% (from 0.0256 to 0.0154 Gy) and 51% (from 0.0463 to 0.0229 Gy), respectively. CONCLUSION: The use of in-plane overlying bismuth radioprotective latex manufactured into form-fitting garments did not affect the diagnostic CT image but reduced the amount of radiation to radiosensitive superficial structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Frush, D. P., Donnelly, L. F., & Rosen, N. S. (2003) · Pediatrics · doi:10.1542/peds.112.4.951 · Cited by 625
Helical CT of the Body: Are Settings Adjusted for Pediatric Patients?
Paterson, A., Frush, D. P., & Donnelly, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760297 · Cited by 422
Pulmonary embolism in pregnancy
Bourjeily, G., Paidas, M., Khalil, H., Rosene-Montella, K., & Rodger, M. (2010) · The Lancet · doi:10.1016/s0140-6736(09)60996-x · Cited by 306
Heyer, C. M., Mohr, P. S., Lemburg, S. P., Peters, S. A., & Nicolas, V. (2007) · Radiology · doi:10.1148/radiol.2452061919 · Cited by 274
Metadata
- Authors
- Hopper, K. D., King, S. H., Lobell, M. E., TenHave, T. R., & Weaver, J. S.
- Venue
- Radiology
- Published
- 1997-12
- Volume
- 205
- Issue
- 3
- Pages
- 853-858
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2163968166
- Cited by
- 194
- References
- 0
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The breast: in-plane x-ray protection during diagnostic thoracic CT--shielding with bismuth radioprotective garments. https://app.cochat.ai/papers/10.1148/radiology.205.3.9393547
- The paper
- Hopper, K. D., King, S. H., Lobell, M. E., TenHave, T. R., & Weaver, J. S. (1997). The breast: in-plane x-ray protection during diagnostic thoracic CT--shielding with bismuth radioprotective garments. Radiology. https://doi.org/10.1148/radiology.205.3.9393547
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.