PURPOSE: To develop and apply a method for the derivation of cancellous bone architectural parameters from in vivo magnetic resonance (MR) images of the distal radius and to evaluate these parameters as predictors of vertebral fracture status in osteopenia. MATERIALS AND METHODS: MR images (137 x 137 x 500-micron3 voxel size) were acquired with a three-dimensional partial flip-angle spin-echo pulse sequence in the distal radius of 36 women. Subjects were classified as healthy or with osteoporosis on the basis of vertebral deformity and bone mineral density (BMD). Images rated as of adequate quality in 20 subjects were processed with a method that is applicable in the limited spatial resolution regime. The method relies on histogram deconvolution to obviate binary segmentation. Cancellous bone structure was treated as a quasi-regular lattice and analyzed with spatial autocorrelation, yielding parameters that quantify intertrabecular spacing, contiguity, and a measure of longitudinal alignment called tubularity. RESULTS: Whereas neither BMD nor any of the structural parameters individually correlated significantly with vertebral deformity fraction, a simple function that involved tubularity and longitudinal spacing predicted deformity fraction well (r = .78, P < .005). CONCLUSION: Histomorphometric parameters characterizing cancellous bone in the distal radius can be derived from in vivo MR microimages and are predictive of vertebral deformity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.206.2.9457185

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Wehrli, F. W., Hwang, S. N., Ma, J., Song, H. K., Ford, J. C., & Haddad, J. G.
Venue
Radiology
Published
1998-02
Volume
206
Issue
2
Pages
347-357
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2073053972
Cited by
188
References
0
FWCI
12.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cancellous bone volume and structure in the forearm: noninvasive assessment with MR microimaging and image processing. https://app.cochat.ai/papers/10.1148/radiology.206.2.9457185
The paper
Wehrli, F. W., Hwang, S. N., Ma, J., Song, H. K., Ford, J. C., & Haddad, J. G. (1998). Cancellous bone volume and structure in the forearm: noninvasive assessment with MR microimaging and image processing. Radiology. https://doi.org/10.1148/radiology.206.2.9457185

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.