CoChat

Superparamagnetic iron oxide particles (SH U 555 A): evaluation of efficacy in three doses for hepatic MR imaging.

Shamsi, K, Balzer, T, Saini, S, Ros, P R, Nelson, R C, Carter, E C, Tollerfield, S, Niendorf, H P · 1998 · Radiology
Cited by 58

The DOI matches its Crossref record.

Abstract

PURPOSE: To evaluate the efficacy of SH U 555 A in three doses for magnetic resonance (MR) imaging in the liver and to establish the best postinjection time point for liver MR imaging. MATERIALS AND METHODS: Pre- and postcontrast image sets obtained in 169 patients after injection of SH U 555 A (randomly, 4, 8, or 16 mumol of iron per kilogram of body weight). Three blinded readers evaluated the precontrast and 10- and 40-minute postcontrast MR images of 54, 58, and 57 patients, respectively. RESULTS: Statistically significant differences were observed in diagnostic confidence between images obtained with a dose of 4 or 16 mumol Fe/kg (P = .011) and in good or excellent improvement, respectively, in delineation of lesions on 10-minute postcontrast images (P = .001). No apparent differences in the efficacy evaluation were seen between the 10- and 40-minute postcontrast imaging time points. CONCLUSION: There was a dose-dependent postcontrast improvement in evaluated efficacy parameters (diagnostic confidence, visual evaluations) after injection of SH U 555 A. Accumulation phase imaging could begin as early as 10 minutes after administration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.206.2.9457187

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 58

Metadata

Authors
Shamsi, K., Balzer, T., Saini, S., Ros, P. R., Nelson, R. C., Carter, E. C., Tollerfield, S., & Niendorf, H. P.
Venue
Radiology
Published
1998-02
Volume
206
Issue
2
Pages
365-371
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2073223432
Cited by
58
References
0
FWCI
5.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Superparamagnetic iron oxide particles (SH U 555 A): evaluation of efficacy in three doses for hepatic MR imaging. https://app.cochat.ai/papers/10.1148/radiology.206.2.9457187
The paper
Shamsi, K., Balzer, T., Saini, S., Ros, P. R., Nelson, R. C., Carter, E. C., Tollerfield, S., & Niendorf, H. P. (1998). Superparamagnetic iron oxide particles (SH U 555 A): evaluation of efficacy in three doses for hepatic MR imaging. Radiology. https://doi.org/10.1148/radiology.206.2.9457187

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.