The DOI matches its Crossref record.
Extranodal malignant lymphoma: detection with FDG PET versus CT.
Abstract
PURPOSE: To evaluate use of functional imaging with positron emission tomography (PET) versus computed tomography (CT) for detection of extranodal lymphoma spread. MATERIALS AND METHODS: Eighty-one consecutive and previously untreated patients with malignant non-Hodgkin lymphoma (n = 43) or Hodgkin disease (n = 38) were examined with 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG) PET and contrast material-enhanced CT. Concordant findings at both CT and FDG PET were regarded as actual locations of disease; discordant results were resolved on the basis of biopsy or follow-up results when possible. RESULTS: Forty-two lesions were identified at both PET and CT, and 19 were verified with biopsy results. PET demonstrated a further 24 lesions. Verification was possible in 15 of these lesions with biopsy (n = 10), magnetic resonance imaging (n = 1), scintigraphic (n = 1), or follow-up (n = 3) results. In 14 of these 15 lesions, PET findings were confirmed (bone marrow, nine; spleen, three; other, two). Seven lesions not visualized at FDG PET were identified at CT, six of which were verified with biopsy (n = 2) or follow-up (n = 4) results. Five of these six CT findings were found to be erroneous. In 13 patients, PET findings led to changes in tumor staging. CONCLUSION: PET may provide more information about extranodal lymphoma than does incremental CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2001) · PubMed · Cited by 943
Spaepen, K., Stroobants, S., Dupont, P., Van Steenweghen, S., Thomas, J., Vandenberghe, P., Vanuytsel, L., Bormans, G., Balzarini, J., De Wolf-Peeters, C., et al. (2001) · Journal of Clinical Oncology · doi:10.1200/jco.2001.19.2.414 · Cited by 465
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
Reske, S. N., & Kotzerke, J. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100626 · Cited by 365
Self-citationBar-Shalom, R., Valdivia, A. Y., & Blaufox, M. D. (2000) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2000.7439 · Cited by 340
Metadata
- Authors
- Moog, F., Bangerter, M., Diederichs, C. G., Guhlmann, A., Merkle, E., Frickhofen, N., & Reske, S. N.
- Venue
- Radiology
- Published
- 1998-02
- Volume
- 206
- Issue
- 2
- Pages
- 475-481
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2014222814
- Cited by
- 321
- References
- 0
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extranodal malignant lymphoma: detection with FDG PET versus CT. https://app.cochat.ai/papers/10.1148/radiology.206.2.9457202
- The paper
- Moog, F., Bangerter, M., Diederichs, C. G., Guhlmann, A., Merkle, E., Frickhofen, N., & Reske, S. N. (1998). Extranodal malignant lymphoma: detection with FDG PET versus CT. Radiology. https://doi.org/10.1148/radiology.206.2.9457202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.