Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record.

Acute Stroke: Improved Nonenhanced CT Detection—Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings

Lev, Michael H., Farkas, Jeffrey, Gemmete, Joseph J., Hossain, Syeda T., Hunter, George J., Koroshetz, Walter J., Gonzalez, R. Gilberto·1999·Radiology

Abstract

PURPOSE: To assess the use of nonstandard, variable window width and level review settings in computed tomography (CT) without contrast material administration in the detection of acute stroke. MATERIALS AND METHODS: Nonenhanced CT was performed in 21 patients with acute (< 6 hours) middle cerebral arterial stroke and nine control patients. Two blinded neuroradiologists rated all scans for presence of parenchymal hypoattenuation. Images were reviewed at a picture archiving and communication system (PACS) workstation, with standard, locally determined center level and window width settings of 20 and 80 HU and with variable soft-copy settings initially centered at a level of 32 HU with a width of 8 HU. Reviewers altered settings to accentuate gray and white matter contrast. RESULTS: With standard viewing parameters, sensitivity and specificity for stroke detection were 57% and 100%. Sensitivity increased to 71% with variable window width and center level settings, without loss of specificity. Receiver operating characteristic analysis revealed a significant improvement in accuracy with nonstandard, soft-copy review settings (P = .03, one-tailed z test). CONCLUSION: In nonehanced CT of the head, detection of ischemic brain parenchyma is facilitated by soft-copy review with variable window width and center level settings to accentuate the contrast between normal and edematous tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.213.1.r99oc10150

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 271

Metadata

Authors
Lev, M. H., Farkas, J., Gemmete, J. J., Hossain, S. T., Hunter, G. J., Koroshetz, W. J., & Gonzalez, R. G.
Venue
Radiology
Published
1999-10
Volume
213
Issue
1
Pages
150-155
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2146840539
Cited by
271
References
0
FWCI
5.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute Stroke: Improved Nonenhanced CT Detection—Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings. https://app.cochat.ai/papers/10.1148/radiology.213.1.r99oc10150
The paper
Lev, M. H., Farkas, J., Gemmete, J. J., Hossain, S. T., Hunter, G. J., Koroshetz, W. J., & Gonzalez, R. G. (1999). Acute Stroke: Improved Nonenhanced CT Detection—Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings. Radiology. https://doi.org/10.1148/radiology.213.1.r99oc10150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.