The DOI matches its Crossref record.
Acute Stroke: Improved Nonenhanced CT Detection—Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings
Abstract
PURPOSE: To assess the use of nonstandard, variable window width and level review settings in computed tomography (CT) without contrast material administration in the detection of acute stroke. MATERIALS AND METHODS: Nonenhanced CT was performed in 21 patients with acute (< 6 hours) middle cerebral arterial stroke and nine control patients. Two blinded neuroradiologists rated all scans for presence of parenchymal hypoattenuation. Images were reviewed at a picture archiving and communication system (PACS) workstation, with standard, locally determined center level and window width settings of 20 and 80 HU and with variable soft-copy settings initially centered at a level of 32 HU with a width of 8 HU. Reviewers altered settings to accentuate gray and white matter contrast. RESULTS: With standard viewing parameters, sensitivity and specificity for stroke detection were 57% and 100%. Sensitivity increased to 71% with variable window width and center level settings, without loss of specificity. Receiver operating characteristic analysis revealed a significant improvement in accuracy with nonstandard, soft-copy review settings (P = .03, one-tailed z test). CONCLUSION: In nonehanced CT of the head, detection of ischemic brain parenchyma is facilitated by soft-copy review with variable window width and center level settings to accentuate the contrast between normal and edematous tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acute ischemic stroke therapy overview
Catanese, L., Tarsia, J., & Fisher, M. (2017) · Circulation Research · doi:10.1161/circresaha.116.309278 · Cited by 341
Merino, J. G., & Warach, S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.129 · Cited by 152
Metadata
- Authors
- Lev, M. H., Farkas, J., Gemmete, J. J., Hossain, S. T., Hunter, G. J., Koroshetz, W. J., & Gonzalez, R. G.
- Venue
- Radiology
- Published
- 1999-10
- Volume
- 213
- Issue
- 1
- Pages
- 150-155
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2146840539
- Cited by
- 271
- References
- 0
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute Stroke: Improved Nonenhanced CT Detection—Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings. https://app.cochat.ai/papers/10.1148/radiology.213.1.r99oc10150
- The paper
- Lev, M. H., Farkas, J., Gemmete, J. J., Hossain, S. T., Hunter, G. J., Koroshetz, W. J., & Gonzalez, R. G. (1999). Acute Stroke: Improved Nonenhanced CT Detection—Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings. Radiology. https://doi.org/10.1148/radiology.213.1.r99oc10150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.