CoChat

Cartilaginous Tumors: Fast Contrast-enhanced MR Imaging

Geirnaerdt, Maartje J. A., Hogendoorn, Pancras C. W., Bloem, Johan L., Taminiau, Antonie H. M., van der Woude, Henk-Jan · 2000 · Radiology
Cited by 230

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: To differentiate between benign and malignant cartilaginous tumors with fast contrast material-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 37 patients, fast contrast-enhanced MR images were obtained in eight enchondromas, 11 osteochondromas, and 18 chondrosarcomas. Start of enhancement-early, within 10 seconds after arterial enhancement; delayed, between 10 seconds and 2 minutes; late, after 5 minutes on spin-echo images-and progression of enhancement were represented with three types of time-signal intensity curves. Findings were correlated with the surgical specimen in 27 cases, curettage material in three cases, and biopsy combined with long-term follow-up findings in seven cases. RESULTS: Start of enhancement and the combination of start and progression of enhancement correlated significantly (P <.001) with benign and malignant tumors. Early enhancement was seen in chondrosarcoma, not seen in enchondroma, and seen in osteochondroma only when growth plates were unfused. The sensitivity was 89%, specificity 84%, positive predictive value 84%, and negative predictive value 89%. Differentiation of malignancy from benignity on the basis of early and exponential enhancement was possible with a sensitivity of 61%, specificity 95%, positive predictive value 92%, and negative predictive value 72%. CONCLUSION: Preliminary results show that in the adult population fast contrast-enhanced MR imaging may assist in differentiation between benign and malignant cartilaginous tumors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.214.2.r00fe12539

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Geirnaerdt, M. J. A., Hogendoorn, P. C. W., Bloem, J. L., Taminiau, A. H. M., & van der Woude, H.-J.
Venue
Radiology
Published
2000-02
Volume
214
Issue
2
Pages
539-546
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2110358372
Cited by
230
References
6
FWCI
4.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.