The DOI matches its Crossref record.
Patients with Breast Cancer: Differences in Color Doppler Flow and Gray-Scale US Features of Benign and Malignant Axillary Lymph Nodes
Abstract
PURPOSE: To document differences in color Doppler flow and gray-scale ultrasonographic (US) features between benign and malignant axillary lymph nodes in women with primary breast cancer. MATERIALS AND METHODS: The longitudinal-transverse axis ratio and hilar status on color Doppler flow and gray-scale US images were prospectively studied for each of 145 axillary nodes in 135 women (74 palpable nodes in 69 women, 71 nonpalpable nodes in 66 women) with primary breast cancer. Intranodal flow distribution was described as peripheral, central, or central perhilar. Resistive and pulsatility indexes and peak systolic velocity were documented. For comparison of benign and malignant features, nodes were divided into three groups: palpable and nonpalpable, palpable, and nonpalpable. RESULTS: Color flow was demonstrated equally well in benign and malignant axillary lymph nodes for all three groups. For all nodes, peripheral flow was significantly higher in malignant (118 of 153 nodes [77%]) than benign (45 of 160 nodes [28%]) nodes (P <.001); central flow and central perhilar flow were significantly greater (P <.002 and <.001, respectively) in benign than malignant nodes. Similar differences were not observed in nonpalpable nodes. The mean longitudinal-transverse axis ratio (+/- SD) was significantly lower in malignant (1.8 +/- 0.6) than benign (2.6 +/- 0.8) nodes. Logistic regression analysis showed peripheral, central, and central perhilar flow and the mean longitudinal-transverse axis ratio to be significant independent predictors of malignancy. CONCLUSION: Color Doppler flow and gray-scale US features applicable to the identification of disease in palpable axillary nodes in patients with breast cancer are not applicable to nonpalpable nodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Axillary Nodal Evaluation in Breast Cancer: State of the Art
Chang, J. M., Leung, J. W. T., Moy, L., Ha, S. M., & Moon, W. K. (2020) · Radiology · doi:10.1148/radiol.2020192534 · Cited by 387
Self-citationBedi, D. G., Krishnamurthy, R., Krishnamurthy, S., Edeiken, B. S., Le-Petross, H., Fornage, B. D., Bassett, R. L., & Hunt, K. K. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2460 · Cited by 332
Qian, C.-N., Berghuis, B., Tsarfaty, G., Bruch, M., Kort, E. J., Ditlev, J., Tsarfaty, I., Hudson, E., Jackson, D. G., Petillo, D., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-2977 · Cited by 312
Peripheral lymphadenopathy: approach and diagnostic tools.
(2014) · Europe PMC (PubMed Central) · Cited by 133
Metadata
- Authors
- Yang, W. T., Chang, J., & Metreweli, C.
- Venue
- Radiology
- Published
- 2000-05
- Volume
- 215
- Issue
- 2
- Pages
- 568-573
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1979374339
- Cited by
- 186
- References
- 0
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patients with Breast Cancer: Differences in Color Doppler Flow and Gray-Scale US Features of Benign and Malignant Axillary Lymph Nodes. https://app.cochat.ai/papers/10.1148/radiology.215.2.r00ap20568
- The paper
- Yang, W. T., Chang, J., & Metreweli, C. (2000). Patients with Breast Cancer: Differences in Color Doppler Flow and Gray-Scale US Features of Benign and Malignant Axillary Lymph Nodes. Radiology. https://doi.org/10.1148/radiology.215.2.r00ap20568
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.