The DOI matches its Crossref record.
Tunneled Infusion Catheters: Increased Incidence of Symptomatic Venous Thrombosis after Subclavian versus Internal Jugular Venous Access
Abstract
PURPOSE: To compare the incidence of symptomatic venous thrombosis after tunneled infusion catheter placement via the internal jugular vein (IJV) versus the subclavian vein (SCV). MATERIALS AND METHODS: A retrospective analysis was performed of 774 catheters placed. Only patients with complete follow-up were included, which yielded a population of 279 catheters in 238 patients (166 in the SCV, 113 in the IJV; total of 26,242 catheter days). All catheters were placed by interventional radiologists with ultrasonographic (in IJV) or venographic (in SCV) guidance. RESULTS: Initial complications were limited to one pneumothorax in the SCV group and one episode of oversedation in the IJV group. There was no difference in infection rates between the two sites (SVC vs IJV: 0.25 vs 0.32 per 100 catheter days; P >.99). The mean dwell time was slightly longer for SCV catheters (103 days) than for IJV catheters (79 days) (P =.04). Venous thrombosis developed in 13% of patients (0.12 per 100 catheter days) with an SVC catheter placed as compared with in 3% (0.04 per 100 catheter days) with an IJV catheter (P =.018). This difference persisted after adjustment for catheter size and side of placement (P =.025). The mean time to thrombosis was 36 days for SCV catheters and 142 days for IJV catheters. CONCLUSION: The IJV is the preferred site for tunneled infusion catheter placement because of the lower incidence of symptomatic venous thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
Guidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Venous Thromboembolism Associated With Long-Term Use of Central Venous Catheters in Cancer Patients
Verso, M., & Agnelli, G. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.08.008 · Cited by 605
Metadata
- Authors
- Trerotola, S. O., Kuhn-Fulton, J., Johnson, M. S., Shah, H., Ambrosius, W. T., & Kneebone, P. H.
- Venue
- Radiology
- Published
- 2000-10
- Volume
- 217
- Issue
- 1
- Pages
- 89-93
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2086704279
- Cited by
- 199
- References
- 0
- FWCI
- 14.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tunneled Infusion Catheters: Increased Incidence of Symptomatic Venous Thrombosis after Subclavian versus Internal Jugular Venous Access. https://app.cochat.ai/papers/10.1148/radiology.217.1.r00oc2789
- The paper
- Trerotola, S. O., Kuhn-Fulton, J., Johnson, M. S., Shah, H., Ambrosius, W. T., & Kneebone, P. H. (2000). Tunneled Infusion Catheters: Increased Incidence of Symptomatic Venous Thrombosis after Subclavian versus Internal Jugular Venous Access. Radiology. https://doi.org/10.1148/radiology.217.1.r00oc2789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.