Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 264

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Deep Venous Thrombosis with Suspected Pulmonary Embolism: Detection with Combined CT Venography and Pulmonary Angiography

Loud, Peter A., Katz, Douglas S., Bruce, Dennis A., Klippenstein, Donald L., Grossman, Zachary D. · 2001 · Radiology

Abstract

PURPOSE: To determine the frequency and location of deep venous thrombosis at computed tomographic (CT) venography after CT pulmonary angiography in a large series of patients clinically suspected of having pulmonary embolism and to compare the accuracy of CT venography with lower-extremity venous sonography. MATERIALS AND METHODS: Venous phase images were acquired from the diaphragm to the upper calves after completion of CT pulmonary angiography in 650 patients (373 women, 277 men; age range, 18-99 years; mean age, 63 years) to determine the presence and location of deep venous thrombosis. Results of CT venography were compared with those of bilateral lower-extremity venous sonography in 308 patients. RESULTS: A total of 116 patients had pulmonary embolism and/or deep venous thrombosis, including 27 patients with pulmonary embolism alone, 31 patients with deep venous thrombosis alone, and 58 patients with both. Among 89 patients with deep venous thrombosis, thrombosis was bilateral in 26, involved the abdominal or pelvic veins in 11, and was isolated to the abdominal or pelvic veins in four. In patients in whom sonographic correlation was available, CT venography had a sensitivity of 97% and a specificity of 100% for femoropopliteal deep venous thrombosis. CONCLUSION: Combined CT venography and pulmonary angiography can accurately depict the femoropopliteal deep veins, permitting concurrent testing for venous thrombosis and pulmonary embolism. CT venography also defines pelvic or abdominal thrombus, which was seen in 17% of patients with deep venous thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.219.2.r01ma26498

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 264

Metadata

Authors
Loud, P. A., Katz, D. S., Bruce, D. A., Klippenstein, D. L., & Grossman, Z. D.
Venue
Radiology
Published
2001-05
Volume
219
Issue
2
Pages
498-502
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2044534173
Cited by
264
References
5
FWCI
11.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Venous Thrombosis with Suspected Pulmonary Embolism: Detection with Combined CT Venography and Pulmonary Angiography. https://app.cochat.ai/papers/10.1148/radiology.219.2.r01ma26498
The paper
Loud, P. A., Katz, D. S., Bruce, D. A., Klippenstein, D. L., & Grossman, Z. D. (2001). Deep Venous Thrombosis with Suspected Pulmonary Embolism: Detection with Combined CT Venography and Pulmonary Angiography. Radiology. https://doi.org/10.1148/radiology.219.2.r01ma26498

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.