AAPM/RSNA Physics Tutorial for Residents: Topics in US: B-mode US: Basic Concepts and New Technology
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Ultrasonography (US) has been used in medical imaging for over half a century. Current US scanners are based largely on the same basic principles used in the initial devices for human imaging. Modern equipment uses a pulse-echo approach with a brightness-mode (B-mode) display. Fundamental aspects of the B-mode imaging process include basic ultrasound physics, interactions of ultrasound with tissue, ultrasound pulse formation, scanning the ultrasound beam, and echo detection and signal processing. Recent technical innovations that have been developed to improve the performance of modern US equipment include the following: tissue harmonic imaging, spatial compound imaging, extended field of view imaging, coded pulse excitation, electronic section focusing, three-dimensional and four-dimensional imaging, and the general trend toward equipment miniaturization. US is a relatively inexpensive, portable, safe, and real-time modality, all of which make it one of the most widely used imaging modalities in medicine. Although B-mode US is sometimes referred to as a mature technology, this modality continues to experience a significant evolution in capability with even more exciting developments on the horizon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
Essentials Of Ultrasound Physics
Zagzebski, J. A. (1996) · Cited by 240
Jespersen, S. K., Wilhjelm, J. E., & Sillesen, H. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000201 · Cited by 205
US extended-field-of-view imaging technology.
Weng, L., Tirumalai, A. P., Lowery, C. M., Nock, L. F., Gustafson, D. E., Von Behren, P. L., & Kim, J. H. (1997) · Radiology · doi:10.1148/radiology.203.3.9169720 · Cited by 180
Clinical evaluation of chirp-coded excitation in medical ultrasound
Pedersen, M. H., Misaridis, T. X., & Jensen, J. A. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00784-6 · Cited by 116 · cited 1×
“Coded ultrasound pulses are a potential means of overcoming this limitation, providing good penetration at the higher frequencies necessary for high spatial resolution ( 10 ).”
Background
Cited by
Feldman, M. K., Katyal, S., & Blackwood, M. S. (2009) · RadioGraphics · doi:10.1148/rg.294085199 · Cited by 332
Chan, V., & Perlas, A. (2011) · Atlas of Ultrasound-Guided Procedures in Interventional Pain Management · doi:10.1007/978-1-4419-1681-5_2 · Cited by 212
Recent Advances in Ultrasound Technology
O’Brien, R. T., & Holmes, S. P. (2007) · Clinical Techniques in Small Animal Practice · doi:10.1053/j.ctsap.2007.05.003 · Cited by 26
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Metadata
- Authors
- Hangiandreou, N. J.
- Venue
- RadioGraphics
- Published
- 2003-07
- Volume
- 23
- Issue
- 4
- Pages
- 1019-1033
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2142900395
- Cited by
- 198
- References
- 5
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AAPM/RSNA Physics Tutorial for Residents: Topics in US: B-mode US: Basic Concepts and New Technology. https://app.cochat.ai/papers/10.1148/rg.234035034
- The paper
- Hangiandreou, N. J. (2003). AAPM/RSNA Physics Tutorial for Residents: Topics in US: B-mode US: Basic Concepts and New Technology. RadioGraphics. https://doi.org/10.1148/rg.234035034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.