CoChat

Multi–Detector Row CT of Hemoptysis

Bruzzi, John F., Rémy-Jardin, Martine, Delhaye, Damien, Teisseire, Antoine, Khalil, Chadi, Rémy, Jacques · 2006 · RadioGraphics
Cited by 219

The DOI matches its Crossref record.

Abstract

Hemoptysis is symptomatic of a potentially life-threatening condition and warrants urgent and comprehensive evaluation of the lung parenchyma, airways, and thoracic vasculature. Multi-detector row computed tomographic (CT) angiography is a very useful noninvasive imaging modality for initial assessment of hemoptysis. The combined use of thin-section axial scans and more complex reformatted images allows clear depiction of the origins and trajectories of abnormally dilated systemic arteries that may be the source of hemorrhage and that may require embolization. Conditions such as bronchiectasis, chronic bronchitis, lung malignancy, tuberculosis, and chronic fungal infection are some of the most common underlying causes of hemoptysis and are easily detected with CT. "Cryptogenic" hemoptysis is common among smokers and warrants subsequent follow-up imaging to exclude possible underlying malignancy. The bronchial arteries are the source of bleeding in most cases of hemoptysis. Contributions from the non-bronchial systemic arterial system represent an important cause of recurrent hemoptysis following apparently successful bronchial artery embolization. Vascular anomalies such as pulmonary arteriovenous malformations and bronchial artery aneurysms are other important causes of hemoptysis. Multi-detector row CT angiography permits noninvasive, rapid, and accurate assessment of the cause and consequences of hemorrhage into the airways and helps guide subsequent management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/rg.261045726

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Bruzzi, J. F., Rémy-Jardin, M., Delhaye, D., Teisseire, A., Khalil, C., & Rémy, J.
Venue
RadioGraphics
Published
2006-01
Volume
26
Issue
1
Pages
3-22
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W1969036120
Cited by
219
References
0
FWCI
7.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multi–Detector Row CT of Hemoptysis. https://app.cochat.ai/papers/10.1148/rg.261045726
The paper
Bruzzi, J. F., Rémy-Jardin, M., Delhaye, D., Teisseire, A., Khalil, C., & Rémy, J. (2006). Multi–Detector Row CT of Hemoptysis. RadioGraphics. https://doi.org/10.1148/rg.261045726

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.