The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T
Abstract
Three-tesla magnetic resonance (MR) imaging offers substantially higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than 1.5-T MR imaging does, which can be used to improve image resolution and shorten imaging time. Because of these increases in SNR and CNR, as well as changes in T1 and T2 relaxation times, an increase in magnetic susceptibility, and an increase in chemical shift effect, many abdominal applications can benefit from 3.0-T imaging. Increased CNR obtained with a gadolinium-based contrast agent improves lesion conspicuity, requires less intravenous contrast material, and improves MR angiography by increasing spatial and temporal resolution. Increased SNR improves fluid conspicuity and resolution for applications such as MR cholangiopancreatography. Increased chemical shift effect also improves spectral resolution for MR spectroscopy. Several potential problems remain for abdominal imaging at 3.0 T. Limitations on energy deposition may require compromises in pulse sequence timing and flip angles. These compromises result in prolonged imaging time and altered image contrast. Magnetic susceptibility and chemical shift artifacts are worsened, but they may be counteracted by shortening echo time, performing parallel imaging, and increasing bandwidth. Radiofrequency field inhomogeneity is also a major concern in imaging larger fields of view and often leads to standing wave effects and large local variations in signal intensity. Many issues related to MR device compatibility and safety have yet to be addressed at 3.0 T. A 3.0-T MR imaging system has a higher initial cost and a higher cost of upkeep than a 1.5-T system does.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Cited by
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
MR elastography: Principles, guidelines, and terminology
Manduca, A., Bayly, P. V., Ehman, R. L., Kolipaka, A., Royston, T. J., Sack, I., Sinkus, R., & Van Beers, B. E. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28627 · Cited by 265
Di Martino, M., Marin, D., Guerrisi, A., Baski, M., Galati, F., Rossi, M., Brozzetti, S., Masciangelo, R., Passariello, R., & Catalano, C. (2010) · Radiology · doi:10.1148/radiol.10091334 · Cited by 259
Metadata
- Authors
- Chang, K. J., Kamel, I. R., Macura, K. J., & Bluemke, D. A.
- Venue
- RadioGraphics
- Published
- 2008-11
- Volume
- 28
- Issue
- 7
- Pages
- 1983-1998
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2121257596
- Cited by
- 198
- References
- 1
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T. https://app.cochat.ai/papers/10.1148/rg.287075154
- The paper
- Chang, K. J., Kamel, I. R., Macura, K. J., & Bluemke, D. A. (2008). 3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T. RadioGraphics. https://doi.org/10.1148/rg.287075154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.