The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
MR Imaging of Entrapment Neuropathies of the Lower Extremity: Part 2. The Knee, Leg, Ankle, and Foot
Abstract
Entrapment neuropathies of the knee, leg, ankle, and foot are often underdiagnosed, as the results of clinical examination and electrophysiologic evaluation are not always reliable. The causes of most entrapment neuropathies in the lower extremity may be divided into two major categories: (a) mechanical causes, which occur at fibrous or fibro-osseous tunnels, and (b) dynamic causes related to nerve injury during specific limb positioning. Magnetic resonance (MR) imaging, including high-resolution MR neurography, allows detailed evaluation of the course and morphology of peripheral nerves, as well as accurate delineation of surrounding soft-tissue and osseous structures that may contribute to nerve entrapment. Familiarity with the normal MR imaging anatomy of the nerves in the knee, leg, ankle, and foot is essential for accurate assessment of the presence of peripheral entrapment syndromes. Common entrapment neuropathies in the knee, leg, ankle, and foot include those of the common peroneal nerve, deep peroneal nerve, superficial peroneal nerve, tibial nerve and its branches, and sural nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gray's Anatomy: The Anatomical Basis of Medicine and Surgery
Gray, H., Williams, P. L., & Bannister, L. H. (1996) · Medical Entomology and Zoology · Cited by 936
Filler, A. G., Haynes, J., Jordan, S. E., Prager, J., Villablanca, J. P., Farahani, K., Mcbride, D. Q., Tsuruda, J. S., Morisoli, B., Batzdorf, U., et al. (2005) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2005.2.2.0099 · Cited by 356
Magic Angle Effects in MR Neurography
Bowen, B. C. (2006) · Yearbook of Neurology and Neurosurgery · doi:10.1016/s0513-5117(08)70339-9 · Cited by 154
Effect of Foot and Ankle Position on Tarsal Tunnel Compartment Pressure
Trepman, E., Kadel, N. J., Chisholm, K., et al. (1999) · Foot & Ankle International · doi:10.1177/107110079902001108 · Cited by 106
MR neurography. MR imaging of peripheral nerves.
Aagaard, B. D. L., Maravilla, K. R., & Kliot, M. (1998) · PubMed · Cited by 90
Effect of lithotomy positions on strain of the obturator and lateral femoral cutaneous nerves
Litwiller, J. P., Wells, R. E., Halliwill, J. R., Carmichael, S. W., & Warner, M. A. A. (2003) · Clinical Anatomy · doi:10.1002/ca.10168 · Cited by 62
MR neurography: diagnostic utility in the surgical treatment of peripheral nerve disorders
Grant, G. A., Goodkin, R., Maravilla, K. R., & Kliot, M. (2004) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2004.02.003 · Cited by 55
Yoon, T. R., Song, E. K., Chung, J. Y., & Park, C. H. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317411960 · Cited by 41
Correlative high-resolution MR-anatomic study of sciatic, ulnar, and proper palmar digital nerve
Hörmann, M., Traxler, H., Ba‐Ssalamah, A., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(03)00188-7 · Cited by 23
Cited by
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Metadata
- Authors
- Donovan, A., Rosenberg, Z. S., & Cavalcanti, C. F.
- Venue
- RadioGraphics
- Published
- 2010-07
- Volume
- 30
- Issue
- 4
- Pages
- 1001-1019
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2128881570
- Cited by
- 318
- References
- 9
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR Imaging of Entrapment Neuropathies of the Lower Extremity: Part 2. The Knee, Leg, Ankle, and Foot. https://app.cochat.ai/papers/10.1148/rg.304095188
- The paper
- Donovan, A., Rosenberg, Z. S., & Cavalcanti, C. F. (2010). MR Imaging of Entrapment Neuropathies of the Lower Extremity: Part 2. The Knee, Leg, Ankle, and Foot. RadioGraphics. https://doi.org/10.1148/rg.304095188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.