Purpose To evaluate the use of artificial intelligence (AI) to shorten digital breast tomosynthesis (DBT) reading time while maintaining or improving accuracy. Materials and Methods A deep learning AI system was developed to identify suspicious soft-tissue and calcified lesions in DBT images. A reader study compared the performance of 24 radiologists (13 of whom were breast subspecialists) reading 260 DBT examinations (including 65 cancer cases) both with and without AI. Readings occurred in two sessions separated by at least 4 weeks. Area under the receiver operating characteristic curve (AUC), reading time, sensitivity, specificity, and recall rate were evaluated with statistical methods for multireader, multicase studies. Results Radiologist performance for the detection of malignant lesions, measured by mean AUC, increased 0.057 with the use of AI (95% confidence interval [CI]: 0.028, 0.087; P < .01), from 0.795 without AI to 0.852 with AI. Reading time decreased 52.7% (95% CI: 41.8%, 61.5%; P < .01), from 64.1 seconds without to 30.4 seconds with AI. Sensitivity increased from 77.0% without AI to 85.0% with AI (8.0%; 95% CI: 2.6%, 13.4%; P < .01), specificity increased from 62.7% without to 69.6% with AI (6.9%; 95% CI: 3.0%, 10.8%; noninferiority P < .01), and recall rate for noncancers decreased from 38.0% without to 30.9% with AI (7.2%; 95% CI: 3.1%, 11.2%; noninferiority P < .01). Conclusion The concurrent use of an accurate DBT AI system was found to improve cancer detection efficacy in a reader study that demonstrated increases in AUC, sensitivity, and specificity and a reduction in recall rate and reading time. Keywords: Breast, Convolutional Neural Network (CNN), Mammography, Tomosynthesis © RSNA, 2019 See also the commentary by Hsu and Hoyt in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Probable Inference, the Law of Succession, and Statistical Inference
Wilson, E. B. (1927) · Journal of the American Statistical Association · doi:10.1080/01621459.1927.10502953 · Cited by 4,476 · cited 1×
“The stand-alone performance of AI was evaluated through case-level sensitivity and specificity at the operating point with Wilson (30) 95% confidence intervals (CIs).”
MethodDiagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678 · cited 1×
“In the United States, computer-aided detection (CAD) is used in approximately 83% of all screening DM (10).”
Method
Cited by
Deep Learning in Medical Image Analysis
Chan, H.-P., Samala, R. K., Hadjiiski, L. M., & Zhou, C. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-33128-3_1 · Cited by 747
Lotter, W., Diab, A. R., Haslam, B., Kim, J. G., Grisot, G., Wu, E., Wu, K., Onieva, J. O., Boyer, Y., Boxerman, J. L., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-01174-9 · Cited by 423
Schaffter, T., Buist, D. S. M., Lee, C. I., Nikulin, Y., Ribli, D., Guan, Y., Lotter, W., Jie, Z., Du, H., Wang, S., et al. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.0265 · Cited by 409
Sechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Medical image analysis based on deep learning approach
Puttagunta, M., & Ravi, S. (2021) · Multimedia Tools and Applications · doi:10.1007/s11042-021-10707-4 · Cited by 321
Dembrower, K., Wåhlin, E., Liu, Y., Salim, M., Smith, K., Lindholm, P., Eklund, M., & Strand, F. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30185-0 · Cited by 290
Artificial Intelligence in Breast Cancer Diagnosis and Personalized Medicine
Ahn, J. S., Shin, S., Yang, S.-A., Park, E. K., Kim, K. H., Cho, S. I., Ock, C.-Y., & Kim, S. (2023) · Journal of Breast Cancer · doi:10.4048/jbc.2023.26.e45 · Cited by 221
“In another reader study for DBT, it has also been observed that AI use not only increased the radiologist performance (0.795 without AI to 0.852 with AI) but also reduced the reading time by up to 50% (from 64.1 seconds without AI to 30.4 seconds with AI) [57].”
BackgroundInfluentialHeterogeneity and predictors of the effects of AI assistance on radiologists
Yu, F., Moehring, A., Banerjee, O., Salz, T., Agarwal, N., & Rajpurkar, P. (2024) · Nature Medicine · doi:10.1038/s41591-024-02850-w · Cited by 200
Combining Human Expertise with Artificial Intelligence: Experimental Evidence from Radiology
Agarwal, N., Moehring, A., Rajpurkar, P., & Salz, T. (2023) · doi:10.2139/ssrn.4505053 · Cited by 161
“However, we can test for 12This principle has been used in computer science (Seah et al., 2021; Conant et al., 2019; Pacilè et al., 2020).”
MethodCombining Human Expertise with Artificial Intelligence: Experimental Evidence from Radiology
Agarwal, N., Moehring, A., Rajpurkar, P., & Salz, T. (2023) · doi:10.3386/w31422 · Cited by 161
Pacilè, S., Lopez, J., Chone, P., Bertinotti, T., Grouin, J. M., & Fillard, P. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020190208 · Cited by 161
“The design was based on similar studies used to test AI-based systems for breast imaging (11,16,17).”
BackgroundMethodHickman, S. E., Baxter, G. C., & Gilbert, F. J. (2021) · British Journal of Cancer · doi:10.1038/s41416-021-01333-w · Cited by 110
Lebovitz, S., Levina, N., & Lifshitz-Assaf, H. (2021) · MIS Quarterly · doi:10.25300/misq/2021/16564 · Cited by 49
Metadata
- Authors
- Conant, E. F., Toledano, A. Y., Periaswamy, S., Fotin, S. V., Go, J., Boatsman, J. E., & Hoffmeister, J. W.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2019-07
- Volume
- 1
- Issue
- 4
- Pages
- e180096
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W2966665347
- Cited by
- 241
- References
- 3
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.