Automated Classification of Radiographic Knee Osteoarthritis Severity Using Deep Neural Networks
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose To develop an automated model for staging knee osteoarthritis severity from radiographs and to compare its performance to that of musculoskeletal radiologists. Materials and Methods Radiographs from the Osteoarthritis Initiative staged by a radiologist committee using the Kellgren-Lawrence (KL) system were used. Before using the images as input to a convolutional neural network model, they were standardized and augmented automatically. The model was trained with 32 116 images, tuned with 4074 images, evaluated with a 4090-image test set, and compared to two individual radiologists using a 50-image test subset. Saliency maps were generated to reveal features used by the model to determine KL grades. Results With committee scores used as ground truth, the model had an average F1 score of 0.70 and an accuracy of 0.71 for the full test set. For the 50-image subset, the best individual radiologist had an average F1 score of 0.60 and an accuracy of 0.60; the model had an average F1 score of 0.64 and an accuracy of 0.66. Cohen weighted κ between the committee and model was 0.86, comparable to intraexpert repeatability. Saliency maps identified sites of osteophyte formation as influential to predictions. Conclusion An end-to-end interpretable model that takes full radiographs as input and predicts KL scores with state-of-the-art accuracy, performs as well as musculoskeletal radiologists, and does not require manual image preprocessing was developed. Saliency maps suggest the model’s predictions were based on clinically relevant information. Supplemental material is available for this article. Keywords: Computer Applications-Detection/Diagnosis, Knee © RSNA, 2020
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736 · cited 2×
“Development of a region proposal model (13,15) that combines automatic joint space identification with KL classification in a single model has been evaluated on portions of the OAI dataset (16), but this approach requires the initial manual annotation of a training set of images.”
BackgroundMethod
Cited by
Groen, A. M., Kraan, R., Amirkhan, S. F., Daams, J. G., & Maas, M. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110592 · Cited by 89
Advancing osteoarthritis research: The role of AI in clinical, imaging and omics fields
Ou, J., Zhang, J., Alswadeh, M., Zhu, Z., Tang, J., Sang, H., & Lu, K. (2025) · Bone Research · doi:10.1038/s41413-025-00423-2 · Cited by 61
Si, L., Zhong, J., Huo, J., Xuan, K., Zhuang, Z., Hu, Y., Wang, Q., Zhang, H., & Yao, W. (2022) · European Radiology · doi:10.1007/s00330-021-08190-4 · Cited by 36
Li, W., Liu, J., Xiao, Z., Zhu, D., Liao, J., Yu, W., Feng, J., Qian, B., Fang, Y., & Li, S. (2024) · Insights into Imaging · doi:10.1186/s13244-024-01719-3 · Cited by 22
Metadata
- Authors
- Thomas, K. A., Kidziński, Ł., Halilaj, E., Fleming, S. L., Venkataraman, G. R., Oei, E. H. G., Gold, G. E., & Delp, S. L.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2020-03-01
- Volume
- 2
- Issue
- 2
- Pages
- e190065
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W3010911449
- Cited by
- 192
- References
- 1
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.