OPTIMAM Mammography Image Database: A Large-Scale Resource of Mammography Images and Clinical Data
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A major barrier to medical imaging research and in particular the development of artificial intelligence (AI) is a lack of large databases of medical images which share images with other researchers. Without such databases it is not possible to train generalisable AI algorithms, and large amounts of time and funding is spent collecting smaller datasets at individual research centres. The OPTIMAM image database (OMI-DB) has been developed to overcome these barriers. OMI-DB consists of several relational databases and cloud storage systems, containing mammography images and associated clinical and pathological information. The database contains over 2.5 million images from 173,319 women collected from three UK breast screening centres. This includes 154,832 women with normal breasts, 6909 women with benign findings, 9690 women with screen-detected cancers and 1888 women with interval cancers. Collection is on-going and all women are followed-up and their clinical status updated according to subsequent screening episodes. The availability of prior screening mammograms and interval cancers is a vital resource for AI development. Data from OMI-DB has been shared with over 30 research groups and companies, since 2014. This progressive approach has been possible through sharing agreements between the funder and approved academic and commercial research groups. A research dataset such as the OMI-DB provides a powerful resource for research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Self-citation
Cited by
Lotter, W., Diab, A. R., Haslam, B., Kim, J. G., Grisot, G., Wu, E., Wu, K., Onieva, J. O., Boyer, Y., Boxerman, J. L., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-01174-9 · Cited by 423
Rahman, A., Hossain, M. S., Muhammad, G., Kundu, D., Debnath, T., Rahman, M., Khan, M. S. I., Tiwari, P., & Band, S. S. (2023) · Cluster Computing · doi:10.1007/s10586-022-03658-4 · Cited by 399
Data Privacy in Healthcare: In the Era of Artificial Intelligence
Yadav, N., Pandey, S., Gupta, A., Dudani, P., Gupta, S., & Rangarajan, K. (2023) · Indian Dermatology Online Journal · doi:10.4103/idoj.idoj_543_23 · Cited by 210
Convolutional neural networks for breast cancer detection in mammography: A survey
Abdelrahman, L., Al Ghamdi, M., Collado-Mesa, F., & Abdel-Mottaleb, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104248 · Cited by 186
Nguyen, H. T., Nguyen, H. Q., Pham, H. H., Lam, K., Le, L. T., Dao, M., & Vu, V. (2023) · Scientific Data · doi:10.1038/s41597-023-02100-7 · Cited by 180
Jeong, J. J., Vey, B. L., Bhimireddy, A., Kim, T., Santos, T., Correa, R., Dutt, R., Mosunjac, M., Oprea-Ilies, G., Smith, G., et al. (2023) · Radiology Artificial Intelligence · doi:10.1148/ryai.220047 · Cited by 92
McKay, F., Williams, B. J., Prestwich, G., Treanor, D., & Hallowell, N. (2022) · Research Involvement and Engagement · doi:10.1186/s40900-022-00357-7 · Cited by 16
Metadata
- Authors
- Halling-Brown, M. D., Warren, L. M., Ward, D., Lewis, E., Mackenzie, A., Wallis, M. G., Wilkinson, L. S., Given-Wilson, R. M., McAvinchey, R., & Young, K. C.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2021-01-01
- Volume
- 3
- Issue
- 1
- Pages
- e200103
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W3015250578
- Cited by
- 182
- References
- 1
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.