Three-dimensional U-Net Convolutional Neural Network for Detection and Segmentation of Intracranial Metastases
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose To develop and validate a neural network for automated detection and segmentation of intracranial metastases on brain MRI studies obtained for stereotactic radiosurgery treatment planning. Materials and Methods In this retrospective study, 413 patients (average age, 61 years ± 12 [standard deviation]; 238 women) with a total of 5202 intracranial metastases (median volume, 0.05 cm3; interquartile range, 0.02–0.18 cm3) undergoing stereotactic radiosurgery at one institution were included (January 2017 to February 2020). A total of 563 MRI examinations were performed among the patients, and studies were split into training (n = 413), validation (n = 50), and test (n = 100) datasets. A three-dimensional (3D) U-Net convolutional network was trained and validated on 413 T1 postcontrast or subtraction scans, and several loss functions were evaluated. After model validation, 100 discrete test patients, who underwent imaging after the training and validation patients, were used for final model evaluation. Performance for detection and segmentation of metastases was evaluated using Dice scores, false discovery rates, and false-negative rates, and a comparison with neuroradiologist interrater reliability was performed. Results The median Dice score for segmenting enhancing metastases in the test set was 0.75 (interquartile range, 0.63–0.84). There were strong correlations between manually segmented and predicted metastasis volumes (r = 0.98, P < .001) and between the number of manually segmented and predicted metastases (R = 0.95, P < .001). Higher Dice scores were strongly correlated with larger metastasis volumes on a logarithmically transformed scale (r = 0.71). Sensitivity across the whole test sample was 70.0% overall and 96.4% for metastases larger than 6 mm. There was an average of 0.46 false-positive results per scan, with the positive predictive value being 91.5%. In comparison, the median Dice score between two neuroradiologists was 0.85 (interquartile range, 0.80–0.89), with sensitivity across the test sample being 87.9% overall and 98.4% for metastases larger than 6 mm. Conclusion A 3D U-Net–based convolutional neural network was able to segment brain metastases with high accuracy and perform detection at the level of human interrater reliability for metastases larger than 6 mm. Keywords: Adults, Brain/Brain Stem, CNS, Feature detection, MR-Imaging, Neural Networks, Neuro-Oncology, Quantification, Segmentation © RSNA, 2021
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 2×
“To provide voxelwise reference-standard segmentations for training, all MRI studies were hand-segmented using ITKSNAP (16) (https://www.”
Method
Cited by
2.5D and 3D segmentation of brain metastases with deep learning on multinational MRI data
Ottesen, J. A., Yi, D., Tong, E., Iv, M., Latysheva, A., Saxhaug, C., Jacobsen, K. D., Helland, Å., Emblem, K. E., Rubin, D. L., et al. (2023) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2022.1056068 · Cited by 32
“Nonetheless, the number of false positives reported for the OUH cohort is among the lowest reported in literature at the time of writing (Zhou et al., 2020b; Hsu et al., 2021; Jünger et al., 2021; Pennig et al., 2021; Rudie et al., 2021).”
BackgroundPflüger, I., Wald, T., Isensee, F., Schell, M., Meredig, H., Schlamp, K., Bernhardt, D., Brugnara, G., Heußel, C. P., Debus, J., et al. (2022) · Neuro-Oncology Advances · doi:10.1093/noajnl/vdac138 · Cited by 31
Wang, T.-W., Shiao, Y.-C., Hong, J.-S., Lee, W.-K., Hsu, M.-S., Cheng, H.-M., Yang, H.-C., Lee, C.-C., Pan, H.-C., You, W. C., et al. (2024) · Mayo Clinic Proceedings: Digital Health · doi:10.1016/j.mcpdig.2024.01.002 · Cited by 23
Metadata
- Authors
- Rudie, J. D., Weiss, D. A., Colby, J. B., Rauschecker, A. M., Laguna, B., Braunstein, S., Sugrue, L. P., Hess, C. P., & Villanueva-Meyer, J. E.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2021-05-01
- Volume
- 3
- Issue
- 3
- Pages
- e200204
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W3135293111
- Cited by
- 57
- References
- 2
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional U-Net Convolutional Neural Network for Detection and Segmentation of Intracranial Metastases. https://app.cochat.ai/papers/10.1148/ryai.2021200204
- The paper
- Rudie, J. D., Weiss, D. A., Colby, J. B., Rauschecker, A. M., Laguna, B., Braunstein, S., Sugrue, L. P., Hess, C. P., & Villanueva-Meyer, J. E. (2021). Three-dimensional U-Net Convolutional Neural Network for Detection and Segmentation of Intracranial Metastases. Radiology: Artificial Intelligence. https://doi.org/10.1148/ryai.2021200204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.