The DOI matches its Crossref record.
Conductivity and Water Uptake of Aromatic-Based Proton Exchange Membrane Electrolytes
Open accessAbstract
Water uptake and proton conductivity as a function of temperature were determined for three aromatic‐based, sulfonic acid‐bearing polymers, plus the perfluoroalkyl sulfonic acid Nafion® 117. Water uptake of submerged, equilibrated samples ranged from less than five water molecules per acid group for a high equivalent weight, sulfonated polyethersulfone to almost fifty waters per acid for a low equivalent weight, sulfonated polyetheretherketone. The most conductive aromatic‐based polymer, sulfonated polyphenylquinoxaline (S‐PPQ), had a room temperature conductivity of . about an order of magnitude less than that of a perfluoroalkyl sulfonic acid under identical conditions. The slope of the S‐PPQ Arrhenius conductivity plot was sufficiently steep that at 180°C, the proton conductivity, , was only a factor of two lower than that of Nafion under similar conditions. The lower conductivity of the aromatic‐based sulfonic acid polymers can be attributed to chain rigidity, lack of ion channels, and lower acidity. © 2000 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alternative Polymer Systems for Proton Exchange Membranes (PEMs)
Hickner, M. A., Ghassemi, H., Kim, Y. S., Einsla, B. R., & McGrath, J. E. (2004) · Chemical Reviews · doi:10.1021/cr020711a · Cited by 2,834
Wang, F., Hickner, M., Kim, Y. S., Zawodzinski, T. A., & McGrath, J. E. (2002) · Journal of Membrane Science · doi:10.1016/s0376-7388(01)00620-2 · Cited by 1,134
PEM Fuel cell and electrolysis cell technologies and hydrogen infrastructure development – a review
Wang, Y., Pang, Y., Xu, H., Martinez, A., & Chen, K. S. (2022) · Energy & Environmental Science · doi:10.1039/d2ee00790h · Cited by 828
Fuel Cell Catalyst Layers: A Polymer Science Perspective
Holdcroft, S. (2014) · Chemistry of Materials · doi:10.1021/cm401445h · Cited by 481
Sulfonated poly(ether ether ketone) membranes for direct methanol fuel cell
Li, L. (2003) · Journal of Membrane Science · doi:10.1016/j.memsci.2003.08.018 · Cited by 469
Influence of Ionomer Content in IrO2/TiO2Electrodes on PEM Water Electrolyzer Performance
Bernt, M., & Gasteiger, H. A. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0231611jes · Cited by 416
Pressurized PEM water electrolysis: Efficiency and gas crossover
Schalenbach, M., Carmo, M., Fritz, D. L., Mergel, J., & Stolten, D. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.09.013 · Cited by 400
Properties of Nafion membranes under PEM water electrolysis conditions
Ito, H., Maeda, T., Nakano, A., & Takenaka, H. (2011) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2011.05.127 · Cited by 393
Kim, Y. S., Dong, L., Hickner, M. A., Glass, T. E., Webb, V., & McGrath, J. E. (2003) · Macromolecules · doi:10.1021/ma0301451 · Cited by 387
Kim, Y. S., Wang, F., Hickner, M., Zawodzinski, T. A., & McGrath, J. E. (2003) · Journal of Membrane Science · doi:10.1016/s0376-7388(02)00507-0 · Cited by 348
A Perspective on Low-Temperature Water Electrolysis – Challenges in Alkaline and Acidic Technology
Schalenbach, M., Zeradjanin, A. R., Kasian, O., Cherevko, S., & Mayrhofer, K. J. J. (2018) · International Journal of Electrochemical Science · doi:10.20964/2018.02.26 · Cited by 305
Sun, C., Negro, E., Vezzù, K., Pagot, G., Cavinato, G., Nale, A., Herve Bang, Y., & Di Noto, V. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.03.056 · Cited by 261
Zhang, L., Ma, C., & Mukerjee, S. (2003) · Electrochimica Acta · doi:10.1016/s0013-4686(03)00257-3 · Cited by 102
Al-Hamed, K. H. M., & Dincer, I. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2021.115062 · Cited by 39
Rangel-Cárdenas, A., & Koper, G. (2017) · Materials · doi:10.3390/ma10060576 · Cited by 33
Li, W., Norris, B. C., Snodgrass, P., Prasad, K., Stockett, A. S., Pryamitsyn, V., Ganesan, V., Bielawski, C. W., & Manthiram, A. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp904192t · Cited by 15
Metadata
- Authors
- Kopitzke, R. W., Linkous, C. A., Anderson, H. R., & Nelson, G. L.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2000
- Volume
- 147
- Issue
- 5
- Pages
- 1677
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2007417775
- Cited by
- 239
- References
- 0
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.