The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
In Situ Current Distribution Measurements in Polymer Electrolyte Fuel Cells
Open accessAbstract
There has been much recent interest and development of methods to accurately measure the current distribution in an operating polymer electrolyte fuel cell (PEFC). This paper presents results from a novel technique that uses a segmented flow field with standard, nonaltered membrane electrode assemblies and gas diffusion layers. Multiple current measurements are taken simultaneously with a multichannel potentiostat, providing high-resolution temporal and spatial distribution data. Current distribution data are shown that display the distributed effects of cathode stoichiometry variation and transient flooding on local current density. It is shown that the time scale for liquid accumulation in gas diffusion layer pores is much greater than that of any electrochemical or gas-phase species transport process. In order to facilitate state-of-the-art PEFC model validation, an idealized single-pass serpentine flow field was used, and the exact geometry is presented. © 2003 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymer Electrolyte Fuel Cell Model
Springer, T. E., Zawodzinski, T. A., & Gottesfeld, S. (1991) · Journal of The Electrochemical Society · doi:10.1149/1.2085971 · Cited by 3,528
Modeling and Experimental Diagnostics in Polymer Electrolyte Fuel Cells
Springer, T. E., Wilson, M. S., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2221120 · Cited by 581
A phenomenological model of water transport in a proton exchange membrane fuel cell
Janssen, G. J. M. (2001) · Journal of The Electrochemical Society · doi:10.1149/1.1415031 · Cited by 164
Cited by
Water transport in polymer electrolyte membrane fuel cells
Jiao, K., & Li, X. (2011) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.06.002 · Cited by 1,086
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1580822 · Cited by 411
Yan, Q., Toghiani, H., & Causey, H. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.03.077 · Cited by 391
Rechargeable redox flow batteries: flow fields, stacks and design considerations
Ke, X., Prahl, J. M., Alexander, J. I. D., Wainright, J. S., Zawodzinski, T. A., & Savinell, R. F. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00072g · Cited by 326
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639158 · Cited by 131
Metadata
- Authors
- Mench, M. M., Wang, C. Y., & Ishikawa, M.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2003
- Volume
- 150
- Issue
- 8
- Pages
- A1052
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2101798625
- Cited by
- 185
- References
- 3
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Situ Current Distribution Measurements in Polymer Electrolyte Fuel Cells. https://app.cochat.ai/papers/10.1149/1.1584440
- The paper
- Mench, M. M., Wang, C. Y., & Ishikawa, M. (2003). In Situ Current Distribution Measurements in Polymer Electrolyte Fuel Cells. Journal of The Electrochemical Society. https://doi.org/10.1149/1.1584440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.