Direct Methanol Fuel Cell Performance of Disulfonated Poly(arylene ether benzonitrile) Copolymers
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper reports the performance of direct methanol fuel cells (DMFCs) using novel disulfonated poly(arylene ether benzonitrile) copolymers derived from hexafluoro-isopropylidene diphenol (6F), 2,6-dichlorobenzonitrile, and 3,3 ' -disulfonated -dichloro diphenyl sulfone (SDCDPS). The membrane electrode assembly (MEA) which employed the sulfonated copolymer with 35 mol % of disulfonated comonomer as the proton exchange membrane had approximately 2-fold lower methanol crossover and slightly higher (about 10%) cell resistance than the MEA using the perfluorosulfonic acid Nafion membrane, resulting in an approximately 50% improvement in selectivity, regardless of membrane thickness. Accordingly, this MEA outperformed the Nafion MEA control in a DMFC single-cell test. For example, 200 mA/cm 2 was obtained (compared with 150 mA/cm 2 for the Nafion MEA) at 0.5 V at a temperature of 80°C and ambient air pressure. Similar experiments performed with nonfluorine-containing biphenol-based sulfonated poly(arylene ether sulfone) copolymers (BPSH) indicated that the compatibility of the polymer electrolyte with the electrodes likely has a critical role in initial DMFC performance. © 2004 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the development of proton conducting polymer membranes for hydrogen and methanol fuel cells
Kreuer, K. D. (2001) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)00632-3 · Cited by 2,969
Development of ionomer membranes for fuel cells
Kerres, J. A. (2001) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)00631-1 · Cited by 1,022
New membranes for direct methanol fuel cells
Jörissen, L., Gogel, V., Kerres, J., & Garche, J. (2002) · Journal of Power Sources · doi:10.1016/s0378-7753(01)00952-1 · Cited by 279
Zhang, L., Ma, C., & Mukerjee, S. (2003) · Electrochimica Acta · doi:10.1016/s0013-4686(03)00257-3 · Cited by 102
Blended Polyphosphazene/Polyacrylonitrile Membranes for Direct Methanol Fuel Cells
Carter, R., Wycisk, R., Yoo, H., & Pintauro, P. N. (2002) · Electrochemical and Solid-State Letters · doi:10.1149/1.1495916 · Cited by 66
Cited by
A review of polymer electrolyte membranes for direct methanol fuel cells
Neburchilov, V., Martin, J., Wang, H., & Zhang, J. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.03.044 · Cited by 873
Park, C. H., Lee, C. H., Guiver, M. D., & Lee, Y. M. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.001 · Cited by 682
Durability challenges of anion exchange membrane fuel cells
Mustain, W. E., Chatenet, M., Page, M., & Kim, Y. S. (2020) · Energy & Environmental Science · doi:10.1039/d0ee01133a · Cited by 677
Self-citationProton exchange membrane fuel cell from low temperature to high temperature: Material challenges
Shao, Y., Yin, G., Wang, Z., & Gao, Y. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.02.065 · Cited by 571
Polymer electrolyte membranes for the direct methanol fuel cell: A review
DeLuca, N. W., & Elabd, Y. A. (2006) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.20861 · Cited by 459
Metadata
- Authors
- Kim, Y. S., Sumner, M. J., Harrison, W. L., Riffle, J. S., McGrath, J. E., & Pivovar, B. S.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2004
- Volume
- 151
- Issue
- 12
- Pages
- A2150
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W1987020537
- Cited by
- 132
- References
- 5
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.