A protonic polymer electrolyte based on polybenzimidazole is proposed for use in a hydrogen sensor, operating at room temperature, in air. The potentiometric response in inert gas containing hydrogen obeys the Nernst equation. In air, the EMF is a mixed potential which results from the hydrogen oxidation and the oxygen reduction. The response time is of the order of 30 s whatever the hydrogen concentration step within the hydrogen partial pressure range from to 1 atm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/1.1837622

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 52

Metadata

Authors
Bouchet, R., Siebert, E., & Vitter, G.
Venue
Journal of The Electrochemical Society
Published
1997-05-01
Volume
144
Issue
5
Pages
L95-L97
ISSN
  • 0013-4651 (ISSN-L)
  • 1945-7111
OpenAlex
W2031840217
Cited by
52
References
0
FWCI
1.51
Type
journal article
Language
en
Open access
bronze
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acid‐Doped Polybenzimidazole as the Membrane of Electrochemical Hydrogen Sensors. https://app.cochat.ai/papers/10.1149/1.1837622
The paper
Bouchet, R., Siebert, E., & Vitter, G. (1997). Acid‐Doped Polybenzimidazole as the Membrane of Electrochemical Hydrogen Sensors. Journal of The Electrochemical Society. https://doi.org/10.1149/1.1837622

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.