Operating Proton Exchange Membrane Fuel Cells Without External Humidification of the Reactant Gases: Fundamental Aspects
Open accessAbstract
Operation of proton exchange membrane fuel cells (PEMFC) without external humidification of the reactant gases is advantageous for the PEMFC system, because it eliminates the need of a gas‐humidification subsystem. The gas‐humidification subsystem is a burden in the fuel cell system with respect to weight, complexity, cost, and parasitic power. A model for the operation of PEMFC with internal humidification of the gases is presented and the range of operating conditions for a PEMFC using dry /air was investigated. The model predicts that dry air, entering at the cathode, can be fully internally humidified by the water produced by the electrochemical reaction at temperatures up to 70°C. This model was experimentally verified for cell temperatures up to 60°C by long‐term operation of a PEMFC with dry gases for up to 1800 h. The current densities, obtained at 0.6 V, were 20 to 40% lower than those measured when both gases were humidified. The water distribution in the cell, while operating with dry gases, was investigated by measuring the amount of product water on the anode and cathode sides. It was found that the back‐diffusion of product water to the anode is the dominant process for water management in the cell over a wide range of operating conditions. The dominating water back‐diffusion also allows internal humidification of the hydrogen reactant and prevents drying out of the anode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of PEM fuel cell durability: Degradation mechanisms and mitigation strategies
Wu, J., Yuan, X. Z., Martin, J. J., Wang, H., Zhang, J., Shen, J., Wu, S., & Merida, W. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.06.006 · Cited by 1,587
Water transport in polymer electrolyte membrane fuel cells
Jiao, K., & Li, X. (2011) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.06.002 · Cited by 1,086
A review of the main parameters influencing long-term performance and durability of PEM fuel cells
Schmittinger, W., & Vahidi, A. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.01.070 · Cited by 819
Two-phase flow and transport in the air cathode of proton exchange membrane fuel cells
Wang, Z. H., Wang, C. Y., & Chen, K. S. (2001) · Journal of Power Sources · doi:10.1016/s0378-7753(00)00662-5 · Cited by 810
Visualization of water buildup in the cathode of a transparent PEM fuel cell
Tüber, K., Pócza, D., & Hebling, C. (2003) · Journal of Power Sources · doi:10.1016/s0378-7753(03)00797-3 · Cited by 561
Metadata
- Authors
- Büchi, F. N., & Srinivasan, S.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1997-08-01
- Volume
- 144
- Issue
- 8
- Pages
- 2767-2772
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W1606522850
- Cited by
- 376
- References
- 0
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operating Proton Exchange Membrane Fuel Cells Without External Humidification of the Reactant Gases: Fundamental Aspects. https://app.cochat.ai/papers/10.1149/1.1837893
- The paper
- Büchi, F. N., & Srinivasan, S. (1997). Operating Proton Exchange Membrane Fuel Cells Without External Humidification of the Reactant Gases: Fundamental Aspects. Journal of The Electrochemical Society. https://doi.org/10.1149/1.1837893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.