Application of Measurement Models to Impedance Spectroscopy: III . Evaluation of Consistency with the Kramers‐Kronig Relations
Open accessAbstract
The Kramers‐Kronig equations and the current methods used to apply them to electrochemical impedance spectra are reviewed. Measurement models are introduced as a tool for identification of the frequency‐dependent error structure of impedance data and for evaluating the consistency of the data with the Kramers‐Kronig relations. Through the use of a measurement model, experimental data can be checked for consistency with the Kramers‐Kronig relations without explicit integration of the Kramers‐Kronig relations; therefore, inaccuracies associated with extrapolation of an incomplete frequency spectrum are resolved. The measurement model can be used to determine whether the residual errors in the regression are due to an inadequate model, to failure of data to conform to the Kramers‐Kronig assumptions, or to noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The timescale identification decoupling complicated kinetic processes in lithium batteries
Lu, Y., Zhao, C.-Z., Huang, J.-Q., & Zhang, Q. (2022) · Joule · doi:10.1016/j.joule.2022.05.005 · Cited by 2,378
Electrochemical Impedance Spectroscopy
(2016) · Encyclopedia of Membranes · doi:10.1007/978-3-662-44324-8_100089 · Cited by 1,580
Electrochemical Impedance Spectroscopy and its Applications
Lasia, A. (2005) · Modern Aspects of Electrochemistry · doi:10.1007/0-306-46916-2_2 · Cited by 1,214
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Self-citationImpedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Self-citation
Metadata
- Authors
- Agarwal, P., Orazem, M. E., & Garcia‐Rubio, L. H.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1995-12-01
- Volume
- 142
- Issue
- 12
- Pages
- 4159-4168
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2113090582
- Cited by
- 251
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Measurement Models to Impedance Spectroscopy: III . Evaluation of Consistency with the Kramers‐Kronig Relations. https://app.cochat.ai/papers/10.1149/1.2048479
- The paper
- Agarwal, P., Orazem, M. E., & Garcia‐Rubio, L. H. (1995). Application of Measurement Models to Impedance Spectroscopy: III . Evaluation of Consistency with the Kramers‐Kronig Relations. Journal of The Electrochemical Society. https://doi.org/10.1149/1.2048479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.